1、 Product Introduction

The highly intelligent integrated negative oxygen ion monitoring station can monitor the concentration of negative oxygen ions in the air 24/7, and can also expand monitoring items according to user needs, such as air temperature, air humidity, etc PM2.5、PM10、 Meteorological factors such as atmospheric pressure, oxygen content, noise, wind speed, and direction. Integrated sensor design, no mechanical displacement, high accuracy, long service life

On site data can be read through the full-color LCD screen, and can also be viewed in real-time on the remote cloud platform/WEB/WeChat official account

On site users can customize and add songs, as well as exceed the standard voice broadcast

2、 Application scope

Tourist attractions, ecological estates, wetland parks, waterfall parks, forest parks, nature reserves, sales offices, schools

3、 Technical parameters

1. Wind speed: Measurement principle ultrasonic, 0-60m/s (± 0.1m/s) resolution 0.01m/s

2. Wind direction: Measurement principle ultrasonic, 0-360 ° (± 2 °) resolution 1 °

3. Air temperature: Measurement principle - diode junction voltage method, -40-60 ℃ (± 0.3 ℃) resolution 0.01 ° C

4. Air humidity: Measurement principle capacitive, 0-100 RH (± 0.3% RH) resolution 0.1% RH

5. Atmospheric pressure: Measurement principle pressure resistance type, 300-1100hPa (± 0.25%), resolution 0.1hPa

6. PM2.5: Measurement principle: light scattering, 0-1000ug/m3 (± 10%) resolution: 1ug/m3

7. PM10: Measurement principle: light scattering, 0-1000ug/m3 (± 10%) resolution: 1ug/m3

8. Noise: Measurement principle capacitive, 30-120dB (± 1.5dB) resolution 0.1dB

9. Negative oxygen ions: Measurement principle: cylindrical electrode suction type, 0-100000/cm ³ (± 10%) resolution 1/cm ³

10. Oxygen content: Measurement principle electrochemical, 0~25% Vol (± 3% FS) resolution 0.1%

11. Screen: Resolution 1920 (RGB) × 1080 (FHD), operating frequency 120Hz, brightness 1500-2500 cd/m2

12. Pole: Carbon steel double column, capable of withstanding 15 level strong typhoons

13. Working environment: temperature -40 ℃ -60 ℃, humidity 0% -100%

14. Data storage: can store raw monitoring data for one year

15. Data transmission: 4G/fiber optic

16. Power supply mode: 220V mains power

17. Power consumption: 500W