1、 Product Introduction

GNSS displacement station is a millimeter level displacement monitoring product implemented using differential RTK technology, which can be widely used in engineering fields such as dam safety monitoring, bridge health detection, landslide warning, etc. This product has high precision, high stability, and real-time data transmission capabilities, and can accurately monitor small displacement changes of target objects in various complex environments. GNSS displacement stations are easy to operate, easy to install, capable of remote monitoring and data analysis, providing strong guarantees for engineering safety. In addition, its powerful data processing capabilities and compatibility enable the product to easily integrate into various monitoring systems, achieve data sharing and fusion, and provide comprehensive and efficient solutions for engineering safety monitoring.

2、 Product parameters

Sensor parameters:

1. Sensor power supply: DC10V-15V

2. Sensor power consumption: 0.25W

3. Static accuracy (differential mode): horizontal ± (2.5mm+1ppm), vertical ± (5mm+1ppm)

4. ☆ Antenna: choke coil antenna, magnetic absorbing material, effectively reducing multipath effects

5. ☆ Communication protocol: Modbus RTU, supports offline calculation of displacement, vertical and horizontal directions of displacement at the device end

6. Support RTCM3 differential data

7. Size: Diameter 360mm, Height 163mm

8. Working environment: -40 ° C~+85 ° C, 0% RH~95% RH (no condensation)

Monitoring station parameters:

9. Station power supply: 30W solar panel, 20AH battery

10. Station power consumption: Sensor+LORA: 0.6W Sensor+LORA+Data upload: 0.96W

11. ☆ Support displacement alarm, displacement output, and displacement angle output in independent working mode (not dependent on cloud platform)

12. Supports 4G, wireless bridge wifi、 Ethernet and other data communication transmission

13. ☆ Support station TCP, HTTP, UDP direct transmission to client platform

Collector parameters:

14. ☆ Supports on-site RS485 output ASCII data format

15. ☆ Support on-site addition of RS485 Modbus RTU environmental sensors

16. Support built-in 4GFPC antenna

Cloud platform parameters:

17. ☆ Support platform forwarding, TCP, HTTP support

18. ☆ The cloud platform supports 3D data viewing, allowing for intuitive viewing of the displacement direction and change amount of observation points

3、 Product installation

Installation requirements:

1. There should be no tall buildings around the reference station or measurement station, and if unavoidable, they should be kept at least 20 meters away.

2. The recommended distance between the reference station and the measurement station (baseline distance) is less than 500 meters, with a maximum of 2KM, and it is recommended to install at the same altitude as much as possible. If the distance is too large, it will lead to a decrease in accuracy.

3. The distance between the reference station and the measurement station should be visible as much as possible, and if it is not visible, high walls, buildings, and other obstructions should be avoided.

4. Prioritize ensuring that the satellite antenna is the highest point within 20 meters.

5. The installation base should be firm to avoid accuracy degradation caused by wind.

6. For specific installation matters, you can also contact the company's after-sales video guidance.


Attention: GNSS displacement monitoring is a high-precision displacement monitoring technology that utilizes positioning satellites such as Beidou and GPS. Its monitoring accuracy strongly depends on the relative relationship between the reference station and the monitoring station, as well as the electromagnetic environment. Long baseline distances can seriously affect monitoring accuracy and even render data invalid (for example, for baseline distances exceeding 2KM or even 10KM, the displacement accuracy may be reduced to the level of 10 centimeters due to the influence of electromagnetic environment and terrain, which is ineffective for displacement monitoring). Therefore, to ensure measurement accuracy, the recommended baseline distance is within 500 meters.