1、 Product Introduction
The SS05 portable multi parameter water quality analyzer is an electrode based water quality analysis instrument that uses fully digital electrodes for detection. It can measure water quality, temperature, conductivity, and other parameters PH、 Ammonia nitrogen and dissolved oxygen parameters. The instrument is equipped with self-developed equipmentftiotThe operating system is easy to operate, stable in performance, accurate in measurement, and has a wide detection range. It is equipped with a high-capacity rechargeable lithium battery, making it convenient for users to conduct water quality testing in the field or laboratory at any time.
2、 Host parameters
| Charging input voltage | 4.5V-5.5V |
| charging current | <2A |
| screen size | 3.5 inches |
| screen resolution | 480*800 ☆ |
| Screen interface | MIPI DSI ☆ |
| USB port | 2 (Supports external mouse, keyboard, 4G, etc.) ☆ |
| Type-C | 1 (Supports external mouse, keyboard, 4G, etc.) ☆ |
| RS485 | 2 (Supports Modbus, JSON, ASC inputs, etc.) |
| External sensor supply voltage | 12V |
| External sensor power supply current | 1A |
| operating system | Ftiot (based on Linux-5.4) ☆ |
| CPU | 2*Cotex-A7,650Mhz ☆ |
| RAM | 512M DDR3 ☆ |
| Flash | 8G-64G |
| OpenGL | ES 2.0 ☆ |
| Wifi | support |
| 4G | optional |
| button | support |
| Capacitive touch screen | support |
| software architecture | B/S ☆ |
| Web access | Support ☆ |
| MTP mode | Support ☆ |
| Multi terminal login | Support ☆ |
| IPv6 | Support ☆ |
| Sensor communication method | RS485、TCP、UDP、Http ☆ |
| Data forwarding method | RS485、TCP、UDP、Http ☆ |
| Remote SSH | Support ☆ |
| remote debugging | Support ☆ |
3、 Sensor parameters and configuration
| serial number | name | measurement range | principle | measurement accuracy | resolution | configuration | remark |
| 1 | temperature | 0~50℃ | High precision digital sensor | ±0.3℃ | 0.01℃ | ✔ | |
| 2 | pH | 0~14(ph) | Electrochemistry (salt bridge) | ± 0.1PH | 0.01 | ✔ | |
| 3 | ORP | -1500mv~1500mv | Electrochemistry (salt bridge) | ± 6mv | 1mV | ||
| 4 | conductivity | 0~5000uS/cm,0~10000uS/cm | Contact electrode method | ± 1.5% | 1uS/cm | ✔ | |
| 5 | TDS | 0-10000ppm 0-200ppt | Contact electrode method | ±1.5%; ±0.1°C | 1ppm 0.01ppt | ||
| 6 | salinity | 0-10000ppm 0-200ppt | Contact electrode method | ±1.5%; ±0.1°C | 1ppm 0.01ppt | ||
| 7 | sludge concentration | 0~20.000g/L | scattered light method | ± 5% (depending on sludge homogeneity) | 0.001g/L | ||
| 8 | turbidity | 0~40NTU (low turbidity) | scattered light method | ± 1% | 0.1NTU | Optional | |
| 0~1000NTU (medium turbidity) | scattered light method | ± 1% | |||||
| 0~3000NTU (high turbidity) | scattered light method | ± 1% | |||||
| 9 | dissolved oxygen | 0~20mg/L | Fluorescence lifetime method | ± 2% | 0.01mg/L | ✔ | |
| 10 | ammonia nitrogen | 0-1000.00mg/L (default) 0-1000mg/l/(customizable) |
Ion selective electrode method | 10% of the reading, ± 0.5 ℃ | 0.01mg | ✔ | Range optional |
| 11 | suspended solids | 0~2000mg/L | scattered light method | ± 5% (depending on sludge homogeneity) | 0.1mg/L | ||
| 12 | residual chlorine | 0~5.00 mg/L | Ion selective electrode method | ± 5% of the reading | 0.01mg/L | The best accuracy is achieved when the flow rate is between 0.42m/s and 0.85m/s | |
| 13 | chloride ion | 0-3500.0mg/L | Ion selective electrode method | ±5% | 0.1mg/L | ||
| 14 | Total Hardness | 0~1000.0mg/L | Ion selective electrode method | ± 10% of the reading | 0.1mg/L | ||
| 15 | cod | 0~500mg/ L | UV254 absorption method | ±5% | 0.1mg/L | COD and chlorophyll are equipped with automatic cleaners to prevent biological attachment and avoid light window pollution, ensuring long-term monitoring stability; Automatic cleaning time and frequency can be set, with a power consumption of 0.7W | |
| 16 | chlorophyll | 0~400ug/L | fluorescence method | R2>0.999 | 0.01ug/L |