Pipe static pressure resistance testing machine
Date: 2025-09-19Read: 16


1.jpg

The static pressure resistance testing machine for pipes is a testing equipment used to determine the long-term pressure resistance and instantaneous burst pressure of plastic pipes and composite pipes at a constant temperature. Widely used in factories, construction quality inspection stations, product quality inspection institutes, research institutions and other fields. Its technical features include multi-channel independent pressure control, automatic data recording, high-precision pressure control, etc. It mainly consists of a pressure control system, a constant temperature water tank, and fixtures.

  Compliant with standards:

GB/T 15560、GB/T 6111、ISO 1167、ASTM D1598、ASTM D1599

  Technical Specifications:

1. Number of test routes: Three (expandable to 12, each independently controlling test pressure and test time)

2. Pressure range: 0-10.00MPa, 0-20.00MPa

3. The maximum working pressure of the main pressure system is 12.00MPa and 20.00MPa

4. High pressure plunger pump

(1) Pressure: 18MPa

(2) Flow rate: 25L/min

(3) Speed: 1450rpm/min

5. Pressure control accuracy:+2% of the upper limit and -1% of the lower limit of the test pressure value

6. Pressure value resolution: 0.01MPa

7. Pressure transmitter: Test pressure sampling frequency of 0.3 milliseconds

8. Timing range: 0-9999h


2.jpg


Simple and safe operation

Comfortable and user-friendly operating interface. User interaction software can easily input experimental parameters and provide a clear overview of the equipment and current experimental status.

The editing and export of experimental results can be easily accomplished through advanced report editors.


Reliable test results

Optional calibration sensor. The pressure sensor can be automatically calibrated before testing or manually calibrated at any time before or during testing.


3.jpg