Product features and uses: This product has high fire resistance and can withstand direct flame combustion without short circuits or short circuit faults for a certain period of time. Therefore, in the event of a fire, it is beneficial to reduce losses. Low smoke halogen-free cables are environmentally friendly cables, especially suitable for industries such as power, large buildings, railways, ships, etc. that require high fire safety requirements.
Product execution standards
Q/HHTZH009.2
Fire resistance characteristics meet the requirements of GB12666.6-90 (IEC331)
Flame retardant and fire-resistant shielded control cable NH-ZR-KVVP 6 * 1.5
1. Rated AC voltage: U0/U 0.6/1KV
2. Maximum long-term working temperature: flame retardant polyvinyl chloride insulation and sheath at 70 ℃ and 105 ℃
Fluoroplastic insulation and sheath at 200 ℃ and 260 ℃
Cross linked polyethylene insulation at 90 ℃
Low smoke halogen-free flame-retardant polyolefin at 70 ℃
Low smoke halogen-free flame-retardant cross-linked polyolefin at 90 ℃ and 120 ℃
3. Low ambient temperature: flame retardant polyvinyl chloride sheath: fixed installation -40 ℃, non fixed installation -15 ℃
Fluoroplastic insulation and sheath: fixed installation -60 ℃; Non fixed laying -20 ℃
4. Fire resistance characteristics:Flame retardant and fire-resistant shielded control cable NH-ZR-KVVP 6 * 1.5
Compliant with IEC331 regulations |
Flame temperature 750 ℃, combustion time 3h, cooling time 12h, additional rated voltage, additional 3A current |
Compliant with GB12666.6-A |
Flame temperature 950-1000 ℃, combustion time 90min, additional rated voltage 3A current |
Compliant with GB12666.6-B class |
Flame temperature 750-800 ℃, combustion time 90min, additional rated voltage 3A current |
5. The temperature for cable installation and laying shall not be lower than 0 ℃
6. Recommended allowable bending radius for laying: Non armored cables shall not be less than 6 times the outer diameter of the cable
Armored cable not less than 12 times the outer diameter of the cable
Fluoroplastic insulation and sheath material cables shall not be less than 8 times the outer diameter of the cable
Flame retardant and fire-resistant shielded control cable NH-ZR-KVVP 6 * 1.5
Fire resistant power cable
model |
Product Name |
NH-VV |
Flame retardant polyvinyl chloride insulated and sheathed fire-resistant control cable |
NH-FF |
Fluoroplastic insulated and sheathed fire-resistant control cable |
NH-VDVD |
Low smoke, low halogen, flame-retardant polyvinyl chloride insulated and sheathed fire-resistant control cable |
NH-YDYD |
Low smoke halogen-free flame-retardant polyolefin insulated and sheathed fire-resistant control cable |
Note: Add 22 after the armored cable model | |
Fire resistant control cable
model |
Product Name |
NH-KVV |
Flame retardant polyvinyl chloride insulated and sheathed fire-resistant control cable |
NH-KVVP |
Flame retardant polyvinyl chloride insulated and sheathed copper wire braided shielded fire-resistant control cable |
NH-KVVP2 |
Flame retardant polyvinyl chloride insulated and sheathed copper tape wrapped shielding fire-resistant control cable |
NH-KFF |
Fluoroplastic insulated and sheathed fire-resistant control cable |
NH-KFFP |
Fluoroplastic insulated and sheathed copper wire braided shielded fire-resistant control cable |
NH-KFFP2 |
Fluoroplastic insulated and sheathed copper tape wrapped shielded fire-resistant control cable |
NH-KVDVD |
Low smoke, low halogen, flame-retardant polyvinyl chloride insulated and sheathed fire-resistant control cable |
NH-KVDVDP |
Low smoke, low halogen, flame-retardant polyvinyl chloride insulated and sheathed copper wire braided shielding fire-resistant control cable |
NH-KVDVDP2 |
Low smoke, low halogen, flame-retardant polyvinyl chloride insulated and sheathed copper wire braided shielding fire-resistant control cable |
NH-KYDYD |
Low smoke halogen-free flame-retardant polyolefin insulated and sheathed fire-resistant control cable |
NH-KYDYDP |
Low smoke halogen-free flame-retardant polyolefin insulated and sheathed copper wire braided shielded fire-resistant control cable |
NH-KYDYDP2 |
Low smoke halogen-free flame-retardant polyolefin insulated and sheathed copper wire braided shielded fire-resistant control cable |
NH-KYJV |
Cross linked polyethylene insulated flame-retardant polyvinyl chloride sheathed fire-resistant control cable |
NH-KYJVP |
Cross linked polyethylene insulated flame-retardant polyvinyl chloride sheathed copper wire braided shielding fire-resistant control cable |
NH-KYJVP2 |
Cross linked polyethylene insulated flame-retardant polyvinyl chloride sheathed copper tape wrapped shielding fire-resistant control cable |