E-mail
1961192594@qq.com
-
Phone
13662632280
-
Address
804, No.1 Zhongxing Road, Buji Street, Longgang District, Shenzhen
Shenzhen Leiao Technology Co., Ltd
1961192594@qq.com
13662632280
804, No.1 Zhongxing Road, Buji Street, Longgang District, Shenzhen
1Function and application areas:
The Xingleiao brand video surveillance multifunctional surge protector (network two in one) is used to protect the AC/DC power supply and network signals of network camera front-end equipment, effectively absorbing the energy impact generated by surges, and introducing the energy into the ground through grounding cables. Select the corresponding product based on the working voltage of the network camera. Multi functional integrated design reduces protection costs and installation difficulties, saves installation space, and greatly improves the comprehensive protection effect of cameras. (36MM rail type network power supply 2-in-1 lightning arrester price)
IITechnical Specifications:
model |
LA-IPC-24V |
LA-IPC-220V |
Power supply section | ||
Rated working voltageUn |
24v |
220V |
Maximum continuous operating voltageUc |
36v |
385V |
Rated working currentIL |
5A |
|
Nominal discharge currentIn(8/20us) |
5KA |
|
Maximum discharge currentImax(8/20us) |
10KA |
|
Protection levelUp |
900V |
900V |
Network section | ||
Maximum continuous operating voltageUc |
Network:6V |
|
Rated working currentIL |
300mA |
|
Nominal discharge currentIn(8/20us) |
1.5KA |
|
Maximum discharge currentImax(8/20us) |
-- |
|
Product Specifications |
120×65×27mm |
|
Protection levelUp |
700V |
|
Maximum transmission rateVs |
1000Mbps |
|
insertion loss |
≤0.5dB |
|
response timetA |
≤10ns |
|
Operating TemperatureT |
-40~+85℃ |
|
Protect the core wire |
1、2、3、6 4 5 7 8 |
|
3、 Wiring diagram
4、 Installation instructions and precautions:
1Before connecting the surge protector in series to the protected equipment, the power must be turned off and live operation is strictly prohibited.
2Installed in series between the lines of the protected equipment, the interface connection must be reliable, and there is an input on the surge protector(IN)Output(OUT)Marking. Connect the output terminal to the protected device, do not connect it in reverse. Otherwise, lightning strikes will damage the surge protector and the equipment will not receive effective protection (refer to the installation wiring diagram).
3The grounding wire (PE) must be reliably connected to the grounding wire of the surge protection system, and the length must be the shortest to achieve the desired protection effect.
4When installing the grounding wire, the equipment should be disconnected to avoid damage caused by strong currents such as welding entering from the grounding end.
5Connect the grounding wire of the surge protector to the metal casing of the equipment to the grounding busbar.
6Surge protectors should be regularly tested during use, and if any malfunctions occur, they should be repaired or replaced in a timely manner to ensure the safety of the protected equipment.
7Non professionals are not allowed to disassemble.(36MM rail type network power supply 2-in-1 lightning arrester price)