Welcome Customer !

Membership

Help

Best Industries (Hong Kong) Limited
Custom manufacturer

Main Products:

smart-city-site>Products

42 square network power meter

NegotiableUpdate on 09/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

42 square network power meter

Product Details

Product description
Overview
42 square network power meters are used for continuous monitoring and control of distribution systems. It can measure various commonly used power parameters, reactive energy, and demand, and can perform remote control, over limit alarm, and analog transmission output function. DO output can be used for over limit alarm or remote control. The threshold value for the alarm can be programmed. All data can be read out through the RS-485 communication port using the MODBUS protocol, and the switch input DI can be used to monitor the status of the switch. The Z series power meters combine high-precision electricity measurement, intelligent energy metering and management, and a simple human-machine interface.


technical indicators
accuracy class U. I is at level 0.2, P and Q are at level 0.5, active energy is at level 0.5, and reactive energy is at level 2
display Programmable LCD or LED display
Input measurement network Three phase three wire, three phase four wire
rated value Voltage: AC 100V, 400V; Current: AC 1A, 5A
overload Duration: 1.2 times instantaneous: voltage 2 times (10 seconds), current 10 times (5 seconds)
power waste Voltage:<1VA (per phase) Current:<0.4VA (per phase)
Impedance Voltage>300k Ω, current<20m Ω
Frequency 50/60Hz±10%
Energy Measurement electric energy Active and reactive energy measurement
power supply scope of work AC、DC 80V~270V
power waste ≤5VA
Output programmable analog quantity 2-channel or 4-channel transmission output: 4-20mA/0-20mA
digital quantity RS-485 interface, MODBUS-RTU protocol
pulse output 2-channel power pulse output, optocoupler relay
Discrete input 4-channel (2-channel) switch input, dry node mode (refer to specification and model description for details)
switch output 4-channel (2-channel) switch output, optocoupler relay (refer to specification and model description for details)
working conditions Environmental temperature: -10~55 ℃, relative humidity ≤ 93%, non corrosive gas environment, altitude ≤ 2500m
Isolation and voltage resistance Input and power supply>2kV, input and output>2kV, power supply and output>1.5kV
insulation resistance ≥100MΩ
List of 42 Square Network Power Meter Models and Functions
model measurement display Peripheral functions (optional, to be specified when ordering)
Transmission output or switch module digital communication electric energy pulse
ELD194Z-2SY U、I、kW、kVar、KVA kVarh、kWh、Hz、cosφ Blue backlit LCD display 4-channel 4-20mA
Or 0-20mA
(Optional)
4-way entry
Route 4 departs
4DI/4DO
(Optional)
RS-485 2-channel power pulse output
ELD194Z-2S4 U、I、kW、kVar、kVarh、kWh、Hz、cosφ
Three rows of LED display
ELD194Z-2S9 I、kWh 4-row LED display
ELD194Z-2S9A U、I、kWh、kVarh 4-row LED display
ELD194Z-2S7 kWh、kVarh Two rows of LED display