Automatic dissolution tester supplied by the manufacturer
Automatic dissolution apparatusIt consists of components such as the box body, control system, electrical system, water bath system, transmission system, sensors, paddle assembly, and basket assembly.

Structural characteristics of automatic dissolution apparatus:
1. When replacing the slurry rod or basket rod, simply operate the keyboard to automatically lift the head of the dissolution tester, making it convenient for slurry or cup replacement operations;
2. The water storage tank is a single or double row, which can be equipped with 6 basket rods or slurry rods, and can be equipped with 8 dissolution cups;
3. It has self checking function and automatic protection function, and can provide various fault alarm signals;
4. The installation position of the water bath can be adjusted and locked, and the vertical axes of the slurry rod, basket rod, and dissolution cup are automatically centered;
5. The microcomputer measurement and control device in the machine has various automatic monitoring functions such as temperature, speed, timing, position, and faults. Users can monitor the operation of the instrument at any time through the display screen and keyboard.
Precautions for using the automatic dissolution apparatus:
1. The power supply should be grounded and well grounded;
2. When there is no water in the water bath, it is forbidden to start the temperature control state, otherwise the heater will be damaged;
3. The water level in the water bath should be kept slightly higher than the liquid level in the dissolution cup, otherwise it will affect the test results;
4. After the temperature control state is activated, if the water in the water bath does not circulate and there is air in the water pump, the pipeline and nozzle should be immediately removed;
5. When cleaning and replacing the water in the water bath, pull down the outlet pipe plug at the bottom left, and then insert the randomly connected outlet pipe plug end into the nozzle socket for drainage. After cleaning, reinstall the original outlet pipe;
6. Do not use organic solvents to clean the shell of the Hao instrument.