Welcome Customer !

Membership

Help

Shanghai Chengwei Instrument Technology Co., Ltd
Custom manufacturer

Main Products:

smart-city-site>Products

Shanghai Chengwei Instrument Technology Co., Ltd

  • E-mail

    692427669@qq.Com

  • Phone

    13671892469

  • Address

    No. 603 Dongzhi Road

Contact Now

Blood Purification Device Extracorporeal Circulation Blood Circuit Comprehensive Tester

NegotiableUpdate on 03/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The comprehensive testing instrument for extracorporeal circulation blood circuit of blood purification device integrates multiple functions, including safety testing of filters and pipeline joints, as well as evaluation of the sealing and flow control of extracorporeal circulation blood circuit. ??
Product Details

Blood Purification Device Extracorporeal Circulation Blood Circuit Comprehensive Tester

Blood Purification Device Extracorporeal Circulation Blood Circuit Comprehensive TesterIntegrate multiple functions, including safety testing of filters and pipeline joints, as well as evaluation of the sealing and flow control of extracorporeal circulation blood pathways. ‌‌

equipmentThe data acquisition system and high-precision sensors used monitor real-time indicators such as pressure and flow during the testing process, and generate detailed performance reports to support data traceability and evaluation. This method reduces the reliance on manual visual inspection, making detection more accurate and data-driven. ‌‌

onecore functionality

Pump tube performance test: Determine the flow deviation of the pump tube within a predetermined pressure range to ensure its stability.

Sealing test: By conducting positive and negative pressure tests, the sealing of each connection in the blood circuit is checked to prevent leakage.

Blood pathway complianceTesting:Quantifying the compliance of blood dialysis by measuring the diameter change of the blood pathway under pressure changes is crucial for ensuring its safety and effectiveness.

2、 Key technical parameters and performance requirements

control system

PLC

operating interface

7Inch color touch screen, language switching between Chinese and English

test project

Pump tube performance; Blood pathway compliance; Positive and negative pressure test for tightness

holding time

1s9999sCan be set

data storage

≥50,000article

flow sensor

0~400ml/minAccuracy: ±2.5%

pressure sensor

-100~100pcs- 760 mmHg ~ +760 mmHg

Test time

99s/99min(Can be set)

power supply

220V50hz

threeKey points of maintenance and compliance

periodic calibrationVerify the pressure sensor to ensure data reliability

Standard complianceYY 0267-2016

safety protectionBuilt in overload protection and power-off memory function to prevent accidental interruption of testing.

fourConfiguration List

host1Taiwan

test software1set

Instruction Manual1this

power cord1root

Certificate of Conformity1copy

Warranty Card1copy

brochure1this

血液净化装置体外循环血路综合性测试仪