Phone
1396218303113862582067
-
Address
Building D8, 7th Floor, Jiacheng Building, 128 Zhongxin Avenue West, Suzhou Industrial Park (Intersection of Zhongxin Avenue West and Xinghai Street)
Suzhou Sainz Instrument Co., Ltd
1396218303113862582067
Building D8, 7th Floor, Jiacheng Building, 128 Zhongxin Avenue West, Suzhou Industrial Park (Intersection of Zhongxin Avenue West and Xinghai Street)
Denver Moisture Analyzer IR-120
One of the most accurate infrared moisture meters in the world, the Monolith weighing system, has an accuracy of 0.1mg and a moisture content accuracy of 0.001%; The built-in weight calibration system ensures that the weighing system is always in the best state
The combination heating mode of infrared metal wire and quartz reflector plate not only preserves the long service life of the metal tube heater, but also makes the heating faster and more uniform, with a designed service life of up to 15 years
Equipped with a built-in blast heating and drying system, the temperature can be more evenly distributed on the surface of the sample, making the test results more accurate. For some baking
The dried raw materials have better repeatability and are closer to the measurement results of the national standard method
Flexible setting of heating modes and analysis methods, optimization of parameter settings, and pre storage of 30 heating programs
■ Easy to clean, when the sample accidentally spills into the sample chamber, simply remove the heating unit and it can be easily cleaned
■ Built in data printer as standard configuration
Denver Moisture Analyzer IR-120 Technical Parameters
|
model |
IR-35 |
IR-60 |
IR-120 |
|
Range ± accuracy |
35g±1mg |
60g |
35g |
|
Average repeatability |
When the initial weight is 1-5g: ± 0.2% |
When the initial sample weight is 1-5 g: 0.2% |
When the initial sample weight is 1-5 g: 0.1% |
|
readability |
0.01% |
1mg, 0.01% moisture content |
1mg, 0.01/0.001% moisture content |
|
Measurement result display mode |
%Moisture,% dry weight,% ratio, residual weight g |
Moisture, dry weight, ratio, residual weight |
Moisture (calculated value), dry weight, ratio, weight loss, residual weight (g or g/kg), g/l |
|
Shutdown method |
Fully automatic, timed mode: 0.1-99 min |
Fully automatic, semi-automatic (1-20 mg/24 s), timed mode (1 x 99.9 min) |
Fully automatic, semi-automatic, timed mode (3 x 999 min), manual |
|
Heating method |
Infrared, metal bend tube heater, long service life; |
Quartz LR heater |
Quartz IR heater |
|
Compliant with FDA/HACCP standards |
Aluminum panel (replacing glass panel) |
------- |
------- |
|
Heating temperature and settings |
40-160 ℃, adjusted at 1 ℃ |
40-210 ℃, adjusted at 1 ℃; Equipped with temperature adjustment kit |
|
|
Heating program |
------- |
standard |
Standard, fast, mild, 3 temperature stages |
|
heating time |
------- |
0.1-99.9 min |
6s~999min |
|
Number of storable programs |
1 piece |
5 of them |
100 of them |
|
Sample tray/external calibration weight |
------- |
Ф90mm / 50 g(E2) |
|
|
Result storage and printing |
Save results for next measurement/compliance with GLP standards |
------ |
------ |
|
Size WxLxH/Net weight |
224 x 366 x191 mm / 5.8 kg |
213x320x181mm / 5.1kg |
350x453x156mm / 8kg |