Phone
16710276909
-
Address
205, Building A, Yinzhou International Building, No. 258 Chengjiaqiao Road, Minhang District, Shanghai
Shanghai Cenxi Technology Co., Ltd
16710276909
205, Building A, Yinzhou International Building, No. 258 Chengjiaqiao Road, Minhang District, Shanghai
测量范围: 0 to 150 mg/L(ppm)O2、0 to 1500 mg/L(ppm)O2、0 to 15000 mg/L(ppm)O2
Unique SMD microcomputer control technology, high-quality narrow band filter, temperature compensated LED optical system, built-in reaction timer, ensuring the results between sample measurement and user *, compact overall design, waterproof sample pool, ensuring fast and accurate measurement, good reproducibility, with calibration function and built-in software adjustment function, applied in scientific research, metrology for sample testing and identification.
Performance Features Highlights
Equipped with unique SMD microcomputer control technology, high-performance narrowband filter and temperature compensated LED light source system, new waterproof design, exquisite portability, and background light display screen.
▷ Factory and user-defined dual calibration function, automatic memory of the last zero calibration, no need for frequent zero calibration, good GLP function, automatic shutdown setting.
Unique IRiM infrared data transmitter [recommended ET214050] design, 16 sets of data storage, can be accessed and read at any time, convenient for on-site data organization and recording, and easy to connect with a computer for data transmission.
Technical Specifications
ET99109
measurement range
0 to 150 mg/L(ppm)O2 、0 to 1500 mg/L(ppm)O2、0 to 15000 mg/L(ppm)O2
resolution
1 mg/L(ppm)、1 mg/L(ppm)、10 mg/L(ppm)
Accuracy @ 20 ° C
±3.5 % F.S.
optical system
Waterproof sample pool, temperature compensated LED optical system;
Dual wavelength of 430 nm and 610 nm, with Δ λ=5 nm; Resolution: 0.01A
Method Standard
Reference water and wastewater standard methods, 18th edition, potassium dichromate/sulfuric acid colorimetric method [ISO 15705:2002]
calibration mode
Automatic zero point calibration, factory calibration, and user-defined dual calibration modes
data management
16 sets of data storage, which can be accessed at any time; Cooperate with ET214050 IRiM infrared data transmitter for convenient data transmission with PC
Power mode
4 x 1.5AAA battery, automatically shuts down after 10 minutes without operation, LCD backlight
Applicable Environment
5 to 40 ° C, RH: 30 to 90% non condensing
Dimensions & Weight
Host size: 190 × 110 × 55mm, host weight: 450g
certification standard
CE certification, IP68 (under 0.1m conditions, 1 hour)
Recommend purchasing accessories
ET99125 microcomputer customized dedicated heating and digestion processor
ET99955 customized specialized chemical oxygen demand [COD-LR] reagent, applicable range: 0 to 150 mg/L (ppm)
ET99974 customized specialized chemical oxygen demand [COD-MR] reagent, applicable range: 0 to 1500 mg/L (ppm)
ET99106 customized chemical oxygen demand [COD-MR] reagent, applicable range: 0 to 15000 mg/L (ppm)
ET2420803 customized special COD standard solution, standard value: 100mg/L, specification: 30mL
ET2420804 customized special COD standard solution, standard value: 500mg/L, specification: 30mL
ET2420805 customized special COD standard solution, standard value: 5000mg/L, specification: 10mL
ET214050 customized dedicated IRiM infrared data transmitter, USB interface, suitable for data transmission to a computer for data, management, and analysis
ET197635 customized glass colorimetric dish cleaning cloth, packaging: 4 pieces/group