features
|
explain
|
|
display
|
60 mm×60mm; 160 × 160 pixels, LCD display with backlight
|
|
weight
|
770g
|
|
size
|
215mm×102mm×49mm(D/W/H)
|
|
keyboard
|
Thin film keyboard
|
|
Battery type
|
Rechargeable NiMH, 4000mAh, 3.6V DC
|
|
Charging time
|
5 hours
|
|
Charging power supply
|
100~240VAC,50~60Hz
|
|
Battery settings
|
13-24-hour measurement mode, background light off;
The 8-12 hour mode provides a 12mA circuit power supply with the background light on.
|
|
Optional 4 alkaline battery settings
|
8-hour measurement mode, background light off;
4-hour measurement mode provides 12mA circuit power supply, with background light on
|
|
working temperature
|
-10~50℃(14~122℉)
|
|
Working temperature during charging
|
0~35℃(32~95℉)
|
|
Storage temperature
|
-20~60℃(-4~140℉)
|
|
humidity
|
0 to 80% non condensing
|
|
Preheating time
|
Effective after 5 minutes of preheating
|
|
Maximum input voltage
|
30V DC,60V DC
|
|
safety standards
|
Derective 73/23/EEC,EN61010-1
|
|
EMC
|
Derective 89/336/EEC,EN61010-1
|
Voltage measurement(-1~60V DC)
|
range
|
resolving power
|
1-year uncertainty
|
|
±0.25V
|
0.001mV
|
0.02%RDG+5µV
|
|
±(0.25~1V)
|
0.01mV
|
0.02%RDG+5µV
|
|
1~25V
|
0.1mV
|
0.02%RDG+0.25mV
|
|
25~60V
|
1mV
|
0.02%RDG+0.25mV
|
|
characteristic
|
parameter
|
|
temperature coefficient
|
<±0.0015%RDG/℃ outside of 18~28℃
<±0.0008RDG/℉ outside of 64.4~82.4℉
|
|
Input impedance
|
>1Mohm
|
|
selectable unit
|
V, mV, µV
|
|
Display refresh rate
|
3/second
|
|
characteristic
|
parameter
|
|
temperature coefficient
|
<±0.0015%RDG/℃ outside of 18~28℃
<±0.0008RDG/℉ outside of 64.4~82.4℉
|
|
Input impedance
|
<7.5ohm
|
|
selectable unit
|
mA, µA
|
|
Display refresh rate
|
3/second
|
Circuit power supply
|
characteristic
|
parameter
|
|
Output current
|
Maximum 25mA, short circuit protection
|
|
output voltage
|
24V±10%
|
|
Output impedance in HART compatible mode
|
300ohm±20%
|
|
range
|
resolving power
|
1-year uncertainty
|
|
±25mA
|
0.0001mA
|
0.02%RDG+1.5µA
|
|
±(25~100mA)
|
0.001mA
|
0.02%RDG+1.5µA
|
☆Electrical signal measurement
|
range
|
resolving power
|
1-year uncertainty
|
|
0.0027~0.5Hz
|
0.000001 Hz
|
0.01%RDG
|
|
0.5~5 Hz
|
0.00001 Hz
|
0.01%RDG
|
|
5~50 Hz
|
0.0001 Hz
|
0.01%RDG
|
|
50~500 Hz
|
0.001 Hz
|
0.01%RDG
|
|
500~5000 Hz
|
0.01 Hz
|
0.01%RDG
|
|
5000~50000 Hz
|
0.1 Hz
|
0.01%RDG
|
|
characteristic
|
parameter
|
|
temperature coefficient
|
Specification valid from 10 to 50℃
|
|
Input impedance
|
>1 Mohm
|
|
Trigger level
|
-1~14v in 1v steps and open collector inputs
|
|
Minimum signal amplitude
|
2Vpp(<10kHz),3Vpp(10~50kHz)
|
|
selectable unit
|
Hz,kHz,cph,cpm,1/Hz(s),1/kHz(ms),1/MHz(us)
|
|
Switching time
|
267ms+1signal period
|
Pulse counting
|
characteristic
|
parameter
|
|
range
|
0 ~ 9999999 pulse
|
|
Input impedance
|
>1Mohm
|
|
Trigger level
|
-1~14V in 1V steps and open collector inputs
|
|
Minimum signal amplitude
|
2Vpp(pulse length>50us),3Vpp(pulse length 10..50us)
|
Switch quantity test
|
characteristic
|
parameter
|
|
|
Potential zero point
|
Test voltage (current)
|
2.8V (0.13A) or 24V (35A)
|
|
Level detection
|
Input impedance
|
>1 Mohm
|
|
|
Trigger level
|
-1~14V in 1V steps
|
☆pressure measurement
Internal pressure module(IPM)
|
Internal module
|
Company
|
range
|
resolving power
|
1Annual uncertainty
|
|
IPM200mC
|
kPa
mbar
iwc
|
±20
±200
±80
|
0.001
0.01
0.01
|
0.05% RDG + 0.05% FS
|
|
IPM2C
|
kPa
bar
psi
|
-100 ~ 200
-1 ~ 2
-14.5 ~ 30
|
0.01
0.0001
0.001
|
0.05% FS
|
|
IPM20C
|
kPa
bar
psi
|
-100 ~ 2000
-1 ~ 20
-14.5 ~ 300
|
0.1
0.001
0.01
|
0.05% FS
|
|
IPM160
|
MPa
bar
psi
|
0 ~ 16
0 ~ 160
0 ~ 2400
|
0.001
0.01
0.1
|
0.05% FS
|
|
Atmospheric pressure module options
|
If an atmospheric pressure module (with an uncertainty of 0.1 kPa) is selected, the above pressure can be measured in absolute pressure.
|
|||
|
characteristic
|
parameter
|
|
temperature coefficient
|
<±0.001%RDG/℃ outside 15~35℃
<±0.0006%RDG/℉ outside 59~95℉
|
|
Maximum overvoltage protection
|
2 times the range
|
|
Pressure interface
|
G 1/8 "internal thread (ISO 228/1) 60 ° internal cone
|
|
Media compatibility
|
Wet parts: AISI316 stainless steel, nitrile rubber
|
|
Pressure unit
|
Pa、hPa、kP、MPa、mbar、lbf/ft2、kgf/cm2、 kgf/m2、 kgf/m2、 at、mmH2O、cmH2O、mH2O、iwc、ftH2O. MmHg, cmHg, mHg, minHg, mmHg (0 ℃), inHg (0 ℃) mmH2O (4 ℃), inH2O (4 ℃) ftH2O (4 ℃) inH2O (60 ℉) mmH2O (68 ℉) ftH2O (68 ℉) tm、 4 users set units
|
|
Display refresh rate
|
2.5 per second
|
|
High precision external pressure module(EXT)
Standard precision external pressure module(EXT)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
User Guide