FT-352High temperature resistivity testing system for conductor materials
FT-352 conductor material
high temperature resistivity test system
Function Overview: Overview
1. Four terminal measurement method
2. Test the material's resistance, conductivity, and resistivity,
3. Cooperate with high-temperature box and high-temperature fixture
4. PC software for data processing and measurement control
Application Description
The conductivity of conductor materials is required to measure temperature changes. The measurement and control software can draw real-time curves of temperature, resistance, resistivity, and conductivity data, as well as report analysis of process data values It has atmosphere protection function
Applicable industries: Cable industries
Used for measuring the resistance, resistivity, and conductivity data of conductor materials by enterprises, universities, and research departments Commonly used for measuring metallic and non-metallic conductor materials
|
Parameter data |
Specification/Model |
FT-352A |
|
FT-352B |
1. Resistance range sheet resistance |
range |
|
10-7~2×107Ω |
10-8~2×104Ω |
2. Range of resistivity |
|
range |
10-7~2×107Ω-cm |
10-8~2×104Ω-cm |
|
Electrical conductivity |
conductivity |
5×10-7~107s/cm |
|
10-4~5×108s/cm |
4. Test current range |
range |
|
1μA,10μA,100µA,1mA,10mA,1000mA |
100uA.1mA.10mA.100mA.1A.10A. |
5. Current accuracy |
|
± 0.1% reading ± 0.1 reading |
6. Resistance accuracy |
|
|
≤0.3% |
≤0.3% |
|
|
PC software interface |
PC software interface |
|
|
Resistance, resistivity, temperature, unit conversion, temperature coefficient, current, voltage, conductivity, curve chart resistance.resistivity.temperature.unit conversion. temperature coefficient. current. voltage. Thickness.Curve graph |
9. Working power supply for resistivity meter |
|
|
power |
Input: AC 220V ± 10%. 50Hz power Consumption:<30W |
|
|
10. Errors/Errors |
≤ 0.5% (standard resistance) samples) |
|
|
Temperature (optional) High temperature (choose to buy) |
Room temperature -400 ℃; 600℃; 800℃; 1000℃; 1200℃; 1400℃; 1600℃Normal temperature-400℃; 600℃; 800℃; 1000℃; 1200℃; 1400℃; 1600℃ 12. Atmosphere protection (gas to be provided by customers) Atmosphere |
|
|
protection(Gas was provided by customers themselves) The commonly used gases are helium (He), neon (Ne), argon (Ar), krypton (Kr), xenon (Xe), radon (Rn), all of which are colorless, odorless, and gaseous monatomic molecules |
The usual gases are: helium (He). neon (Ne). argon (Ar). krypton (Kr). xenon (Xe). and radon (Rn). |
|
|
all in colorless. odorless. gaseous monatomic molecules. 13. Temperature accuracy |
precision Temperature value: ≤ 1-3 ℃; Temperature control accuracy: ± 1 ° C |
|
|
Blunt temperature values:≤1-3℃; Temperature control precision:±1°C Heating rate: |
rate of temperature increase |
|
|
Starting from room temperature, it takes 15 minutes to reach 400 ℃ to 800 ℃; 800 ℃ -1200 ℃ takes 30 minutes; 1400 ℃ -1600 ℃ takes 250-300 minutes About 15 minutes at room |
temperature to 400 ℃. 800 ℃; 800 ℃ to 1200 ℃ need 30 minutes; 1400 ℃ to 1600 ℃ to 250 minutes. 300 minutes |
|
|
high temperature materials High temperature material |
Using composite ceramic fiber materials, it has the characteristics of vacuum forming and high temperature powder retention Adopt composite ceramic |
|
pc software
PC software
Test a set of PC software, USB communication interface, software interface synchronously displays, analyzes, saves and prints data!
One set test PC software.
USB communication interface. software interface synchronization display.
analysis. save and print data!
Electrode material
Electrode materials
Tungsten electrode or molybdenum electrode
Tungsten electrode or
molybdenum electrode
sample requirements
sample requirementThe sample length requirement is greater than 13mm, and the minimum sample width is 1mm
The sample length
requirement is greater than 13mm and sample width minimum 1mm
Standard configuration (optional):
Except standard
configuration (optional)
1 set of computer and printer; 2. 1-5 standard resistors;
1 . One set computer and
printer 2.Standard resistance 1 to 5pcs
Whole machine schematic diagram
Working principle of the whole machine
Operation process and steps
1. System connection: Connect various components, control systems, power supplies, and USB communication interfaces;
2. Whether the connection of the debugging system is normal can be seen from the data changes on the PC software and resistivity tester
3. Set the required temperature in sections on the high-temperature box, or set a temperature without sections For specific operation of high-temperature box instruments, please refer to the "Temperature Instrument Operation Manual"
4. Wait for the sample to enter the high-temperature box through the high-temperature fixture
1.5. Open the inert gas input valveDuring the real-time temperature rise, the real-time curve of the sample resistance changes
2.When the temperature reaches the set value, heating will automatically stop
8. After the test is completed, turn off the high-temperature power and leave it on for 10-20 minutes
3.9. Use high-temperature gloves to move the fixture up and out of the high-temperature box
10. Use tweezers to remove the sample