Welcome Customer !

Membership

Help

Shanghai Yifeng Instrument Equipment Co., Ltd
Custom manufacturer

Main Products:

smart-city-site>Products
Product Categories

Shanghai Yifeng Instrument Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 706, Building 5, Xizi International Center, 898 Xiuwen Road, Minhang District, Shanghai (201199)

Contact Now

GRIMMEDM365 Environmental Particle Monitoring System

NegotiableUpdate on 04/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The EDM365 online environmental particulate aerosol particle size spectrometer developed and produced by GRIMM Aerosol Technology Company in Germany adopts the principle of laser scattering to simultaneously obtain the mass concentration values of PM10, PM25, and PM10 in the ambient atmosphere.
Product Details

GRIMM EDM365 Environmental Particle Monitoring System

Simultaneously monitor PM10, PM2.5, PM1.0, and TC in real-time

The EDM365 online environmental particulate/aerosol particle size spectrometer developed and produced by GRIMM Aerosol Technology Company in Germany uses laser scattering principle to simultaneously obtain the mass concentration values of PM10, PM2.5, and PM1.0 in the ambient atmosphere. Compliant with European standards EN12341 (PM10) and EN14907 (PM2.5) and certified by the US EPA (PM2.5). System integration design, equipped with meteorological parameter measurement sensors, can simultaneously monitor relative humidity, temperature, wind speed, wind direction, precipitation, and air pressure, and transmit monitoring data online. Optional gas sensor, capable of monitoring gaseous pollutants such as VOCs and NOx、O3And with CO.

Product advantages

Advantage

Fully automatic, anti oscillation, low maintenance

Outdoor movable stainless steel protective box with ventilation and heating equipment

3 PM particle sizes, TC value

Particle size analysis, PAH, and meteorological parameters (optional)

Can monitor relative humidity, temperature, and air pressure

GESYTEC protocol; Data recording card, RS-232 port

Filter membrane collection, can be used for chemical analysis and weight analysis (analysis)

No radioactive source, no SVC loss (Nafion dehumidification)

Product Application

Application

Environmental monitoring station

Mobile PM monitoring

Analysis of aerosol particle size

Monitoring of hotspot areas

Identification of Pollution Sources

Technical Specifications

Parameter

Certification is the same as EDM180: EN12341, EN14907, US-EPA, GOSTR

Measurement principle: 90 ° laser scattering

Laser: Laser diode, wavelength 660nm

Power supply: Pmax.=60mW, normal 0.5/30mW CW (multi-channel)

Particle size channels: 11 nanochannels, 0.25/0.28/0.3/0.35/0.45/0.45/0.5/0.58/0.65/0.7/0.8/1.0,

20 micron channels, 1/1.3/1.6/2/2.5/3/3.5/4/5/6.5/7.5/8.5/10/12.5 15/17.5/20/25/30/32

Measurement mode:

EDM365-C PM10 and PM2.5 (Basic Version)

EDM365-CE PM10+TSP

EDM365-D PM10、PM2.5、PM1 和TC

EDM365-E 0.25~>32 μ m 31 particle size channels, or PM10, PM2.5, PM1, and TC

EDM365-MC 0.25~>32 μ m 31 particle size channels, as well as PM10, PM2.5, PM1, and TC

Particle concentration: 1~2 million p/L

Mass concentration: 0.1 μ g/m3~100 mg/m3

Weight calibration: extrapolation method, can be calibrated using filter membrane weighing method (EN12341, EN14907)

Sampling flow rate: 1.2LPM ± 5%

Cleaning gas flow rate: 0.3LPM, automatically running in standby mode

Dehumidification: Nafion drying tube, no heating

Repeatability: 5% maximum range

Operation: Panel operation or PC operation (software or super terminal)

LCD screen: 2 x 16 characters

Self check: automatically performed before each measurement

Measurement interval: 1 minute during continuous operation

Storage interval: 1min~1h

Data exchange: PC, RS232, data logger, data collector

Data output: LCD displays the average particle mass concentration per minute

Data interface: ASCII: RS-232 (baud rate 9600, bit 8, no parity check, stop bit 1 (Xon/Xoff);

GESYTEC: Baud rate 19200 1200, label and serial number optional

Data protocol: ASCII or GESYTEC

Memory card: 1MB and 4MB, battery support, storage interval is 1-60 minutes

Analog input: 3 (0-10V), resolution of 10 bits (ca. 10 mV)

Size: 70.0 × 48.9 × 27.1 cm

Weight: 36kg

Power supply: 220V-50Hz or 110V-60Hz

Power: max.P=150W, I (max)=1.4A

Maximum working altitude: 1000 meters, with PC control for flow regulation up to 5000 meters

Working environment: 4~40 ℃, RH<95%, no condensation

Storage and transportation conditions: -20~50 ℃, RH<95%, no condensation

Sample gas requirements: -20~60 ℃, RH<95%, no condensation

Pressure range: 0~-30 mbar (instantaneous)

Attachment

Accessory

177B 32-bit software

365-SVC SVC update package, including dual sampling tubes for Nafion dehumidification and heating to 300 ℃ heater

365G various gas sensors (according to customer needs)

119 179 Special Small Parts

318 Second Year Spare Parts

157L humidity, temperature, and pressure sensor

158L humidity, temperature, pressure, wind direction and speed sensors

159L humidity, temperature, pressure, wind direction, wind speed, and precipitation sensors

Additional components for 180-DF 182 sampling tube (used in extremely cold areas)

160V2 PM10, PM2.5, and PM1 analog output converter, outputting 0~10V or 4~20mA, with a range of 0~6000 μ g/m3

The 1142.M5 data collector can transmit data to any PC to obtain and display real-time measurement data. The data from EDM365 and the connected sensors can be collected and combined into a set of data simultaneously, allowing for remote control of the instrument. 2GB of memory, upgradable to 4GB.

1142.A2 1MB 存储

1142. A4 4MB memory card

186 on-site testing components

Data recording system

The 1142.M5 data recording system integrates the data recording system and remote control system, connecting the GRIMM monitor with other sensors. The integrated interface is connected to the webpage and can be operated using TCP/IP protocol.

Automatic filter membrane sampling

For laboratory analysis, the sampling time and frequency can be set and changed by computer control, and more than 14 filter membranes (25-47mm) can be automatically replaced.

gas sensor

The gas system can be equipped with two different toxic gas sensors (CO, H)2S、SO2、NOxOr NH2)And a PID (photoionization detection) sensor can be installed in EDM365 and connected to the 1142.M5 data logger.

The 365G3xx gas sensor can continuously monitor various harmful organic and inorganic gases, oxygen, and flammable gases. Up to 5 sensors can be installed for emergency monitoring, industrial hygiene, and many other monitoring tasks. It is possible to combine standard gas sensors with special toxic gas sensors and PID for monitoring a wide range of toxic gases.

Gas sensor specifications:

365G313 VOC/H2S/SO2Electrochemical sensor
365G312 VOC/H2S/CO electrochemical sensor
365G315 VOC/H2S/NO2Electrochemical sensor
365G325 VOC/CO/NO2Electrochemical sensor
365G35C VOC/CO2/NO2Electrochemical sensor

Gas sensor specifications:

monitoring parameters Range/Resolution
VOCs 0~199ppm/0.1ppm or 200~2000ppm/1ppm
CO 10 ~ 2000ppm/10ppm
H2S 0 ~ 100ppm/1ppm
SO2 0 ~ 20ppm/0.1ppm
NO2 0 ~ 20ppm/0.1ppm

software operation

Software

The EDM series monitoring system runs using Labview software developed by GRIIM, which can display and calculate data in real time. All data is stored on memory cards or data loggers, and there will be no data loss. Due to the system being produced in Germany, all systems use the standardized GESYTEC network protocol. However, many other operating modes can be used through the GRIMM software package. Each device can be connected to a computer via RS232, and data logger can be used to collect data at intervals of 1 minute or more. Fully automated testing, control system monitors instrument performance and reports possible errors.