Phone
180-0162-3858
-
Address
Unit F1-2, 4th Floor, Building 18, 481 Guiping Road, Caohejing Development Zone, Shanghai 200233
Maoxin Industrial (Shanghai) Co., Ltd
180-0162-3858
Unit F1-2, 4th Floor, Building 18, 481 Guiping Road, Caohejing Development Zone, Shanghai 200233
HCS621GXY INSTEC Universal Microscopic Cold and Hot Stage

**Used for image representation of various thermal transformation processes, it can be directly used to observe the morphological changes of samples during heating or cooling, as well as the shape during crystallization
Changes in structure, color, size, and quantity.
Temperature range -190 ℃~600 ℃
Temperature stability ± 0.05 ℃
Atmosphere protection, vacuum, high pressure
Sample area Φ 26mm
Adapt microscope transmission reflection upright and inverted
Product Introduction:
HCS621GXY is designed specifically for microscopes/spectrometers. This hot and cold table can control the temperature within the range of -190 ℃ to 600 ℃, while allowing optical observation and sample gas environment control.
The top cover and bottom shell of the hot stage form an airtight chamber, which can be filled with protective gases such as nitrogen to prevent the sample from frosting at negative temperatures or oxidizing at high temperatures.
In addition, the cold and hot table is equipped with an XY sample differential movement ruler that can move samples from outside the sealed chamber. In addition, there is also a vacuum chamber model HCS421VXY available.
Features:
Suitable for microscopes/spectrometers |
-190 ℃~600 ℃ programmable temperature control (negative temperature requires liquid nitrogen refrigeration system) |
Heating zone with a diameter of 26 mm and a through-hole |
Differential moving ruler for moving samples in the XY direction |
An airtight chamber that can be filled with protective gas (there are also vacuum chamber models available) |
Can be controlled from a thermostat or computer software, with software SDK available |
Temperature control parameters:
temperature range |
-190 ℃~600 ℃ (negative temperature requires liquid nitrogen refrigeration system) |
Heating block material |
silver |
Sensor/Temperature Control Method |
100 Ω Platinum RTD/PID Control |
*High heating/cooling speed |
+150 ℃/min (at 100 ℃) -50 ℃/min (at 100 ℃) |
*Small heating/cooling speed |
±0.01℃/min |
temperature resolution |
0.01℃ |
temperature stability |
±0.05℃(>25℃),±0.1℃(<25℃) |
Software features |
Temperature control rate can be set, temperature control program can be set, and temperature control curve can be recorded |
Optical parameters:
Applicable optical path |
Transmitting light path and reflecting light path |
Window panel |
Detachable and replaceable window panels |
*Working distance of small objective lens |
WD in 5mm * cross-sectional view |
*Small spotlight working distance |
11.5 mm * CWD in cross-sectional view |
light-transmitting hole |
In the cross-sectional diagram, the diameter is 2 mm and the diameter is VA |
Observation of the upper cover window panel |
Window panel range is 18mm, * large viewing angle ± 58 ° * θ 1 in the cross-sectional view |
Observation of bottom window panel |
Window panel range is 18mm, * large viewing angle ± 19 ° * θ 2 in the cross-sectional view |
Defrosting of window panels under negative temperature |
Blow defrosting pipeline |
Structural parameters:
Heating area/sample area |
Ø26 mm *When using an XY ruler, the sample area is determined by the sample substrate |
Sample cavity height |
2.5 mm *Sample * large thickness=sample cavity height - sample substrate thickness |
Sample substrate |
Default is quartz crucible (inner diameter>9mm/thickness 0.5mm) *Can be replaced with other options according to user needs |
lofting |
Pull out the upper cover horizontally and insert the sample |
Sample XY moving ruler |
The sample can be moved from outside the sealed chamber with a resolution of 10 μ m and a stroke of 10mm |
Atmosphere control |
Airtight chamber, capable of being filled with protective gas |
Shell cooling |
Can circulate water to maintain the shell temperature near room temperature |
Installation method |
Horizontal or vertical installation |
Platform size/weight |
159.7 mm x 86 mm x 22 mm / 500g |
Configuration List:
Basic Configuration |
HCS621GXY cold and hot table, mK2000B temperature controller |
Optional accessories |
Cold and hot table installation bracket, liquid nitrogen refrigeration system, shell circulating water cooling system 、 Vacuum system (* for vacuum models) |
For Instec temperature control devices: temperature control accessories
Used for pairing with Instec hot and cold tables, Instec temperature control probe tables, Instec temperature control wafer clamps, Instec hot and cold plates, and Instec customized temperature control devices.
Temperature control accessories series:
Installation bracket: used to fix the temperature control device on the user's equipment |
MK2000B thermostat, including Instec APP temperature control software, temperature control device must be selected |
LN2-SYS liquid nitrogen refrigeration system: liquid nitrogen pump+liquid nitrogen tank+liquid nitrogen pipeline |
Shell circulating water cooling system, Peltier type temperature control device must be selected |
MITO series temperature controlled microscope camera, including control software |
LWDC2 long working distance spotlight |
Vacuum system: including vacuum pump and vacuum pipeline, used for vacuum type temperature control device |
LN2-SYS liquid nitrogen refrigeration system |
|
It is mainly divided into two parts: liquid nitrogen pump and liquid nitrogen tank. When in use, the temperature control device needs to be connected in series between the liquid nitrogen tank and the liquid nitrogen pump using a pipeline, The temperature control device heating block is embedded with a closed inlet and outlet pipeline, and the liquid nitrogen pump is controlled by mK2000B to extract liquid nitrogen from it The tank is sucked into the heating block of the temperature control device to achieve active cooling of the temperature control device.
|
MK2000B thermostat
Supports constant temperature, constant rate temperature change, pause, and programmed temperature control functions. It has the characteristics of multi segment PID control for hot and cold * *, and can store 4 sets of 20 segment calibration tables. It can be controlled by * * or through the Instec APP software. | |
temperature resolution |
± 0.001 ℃ (thermistor), ± 0.01 ℃ (RTD), ± 0.1 ℃ (thermocouple) |
control interface |
USB virtual serial port can choose other interfaces |
optional item |
LVDC linear adjustable DC power supply, used to reduce electrical noise |
Temperature control software |
InstecAPP, Can provide multilingual SDK |


Shell circulating water cooling system:
Cooling of the casing/base of the temperature control device. When the temperature control device is heated/cooled, the temperature of the casing/base will be very hot/cold, which can harm surrounding personnel, equipment, and even the equipment itself. Using circulating water to keep the temperature of the casing around room temperature can effectively prevent this disaster.

Universal hot and cold table sample mobile airtight type
HCS621GXY
Universal hot and cold table sample mobile airtight type