NDK200-2 nitrogen blower
Product Description: How to TranslateThe NDK200-2 nitrogen blower is mainly used for concentration or preparation of large quantities of samples (such as drug screening, hormone analysis, liquid phase, and sample preparation in mass spectrometry analysis). Working principle: By blowing nitrogen into the surface of the heated sample, the solvent in the sample evaporates and separates quickly, thereby achieving the goal of oxygen free concentration of the sample and keeping it purer. Using a nitrogen blower instead of a commonly used rotary evaporator for concentration can concentrate dozens of samples simultaneously, saving time and efficiency.
Product Features
1. The heater rapidly heats the sample to the evaporation temperature, while the gas is blown onto the surface of the solution through a gas needle, promoting rapid evaporation of the solution and concentration of the sample.
2. The position of the gas needle in the gas chamber can be changed to make it suitable for different test tubes.
3. The height of the air chamber can be adjusted, and the standard needle length is 150mm.
4. There are 12 airway control switches that do not waste gas.
5. When concentrating toxic solvents, the entire system can be placed in a fume hood.
6. Built in over temperature protection device, automatic fault detection and alarm function.
7. LED display screen, temperature synchronous display, time decreasing display, easy and convenient operation.
8. Standard equipment includes an air chamber and an adjustable bracket.
Product Technical Parameters
Product Model |
NDK200-1Nitrogen blower |
NDK200-2Nitrogen blower |
|
||
temperature range |
Room temperature+5 ℃ -150 ℃ |
|
|||
warm-up time |
≤ 30 minutes (from 40 ℃ to 150 ℃) |
|
|||
Temperature accuracy (40~100 ℃) |
±0.5℃ |
|
|||
Temperature accuracy (100~150 ℃) |
±1℃ |
|
|||
Temperature stability (100 ℃) |
±0.5℃ |
|
|||
Number of modules placed |
1 piece |
2 pieces |
|||
Set the longest time possible |
99h59min |
|
|||
nitrogen flow rate |
0—10L/min |
|
|||
nitrogen pressure |
≤0.1MPa |
|
|||
Zui High Power |
200W |
400W |
|
||
Overall dimensions |
230x200x500 mm |
280x260x500 mm |
|
||
Module model selection |
Refer to NDK200 series replaceable modules |
|
|||
Conventional configuration of the instrument
Users can select modules from the DT01A-DT18 specifications, which can be interchanged. The standard configuration is the DT06 module. Optional flow control valve.
NDK200 series replaceable modules
model |
Test tube diameter |
Number of test tubes |
Module size mm |
DT<01A> |
<6 mm> |
12 |
95.5X76.5X50 |
DT<02A> |
<7 mm> |
12 |
95.5X76.5X50 |
DT03A |
<10 mm> |
12 |
95.5X76.5X50 |
DT04A |
<12 mm> |
12 |
95.5X76.5X50 |
DT05A |
<13 mm> |
12 |
95.5X76.5X50 |
DT06 |
<15 mm> |
12 |
95.5X76.5X50 |
DT07 |
<16 mm> |
12 |
95.5X76.5X50 |
DT08 |
<19 mm> |
12 |
95.5X76.5X50 |
DT09A |
<20 mm> |
6 |
95.5X76.5X50 |
DT10A |
<26 mm> |
6 |
95.5X76.5X50 |
DT11A |
<28 mm> |
4 |
95.5X76.5X50 |
DT12A |
<40 mm> |
4 |
95.5X76.5X50 |
DT<13A> |
0.5 ml centrifuge tube |
12 |
95.5X76.5X50 |
DT14A |
1.5 ml centrifuge tube |
12 |
95.5X76.5X50 |
DT15A |
2.0 ml centrifuge tube |
12 |
95.5X76.5X50 |
DT16A |
0.2ml |
12 |
95.5X76.5X50 |
DT17 |
tablet |
96 well enzyme-linked immunosorbent assay plate |
78X114X26 |
DT18 |
Can be customized |
Can be customized |
Can be customized |
Product keywords: NDK200-1A 96 well nitrogen blower, NK200-1B visual nitrogen blower, NDK200-2 nitrogen blower, NDK200-1 nitrogen blower