1Product Introduction
The human body static discharge alarm is an instrument suitable for the discharge of human body static electricity in flammable, explosive, and anti-static places. Its characteristic lies in the design of a reasonable human body static discharge resistor, which effectively controls the human body static discharge, prolongs the human body static discharge time, reduces the instantaneous human body static discharge energy, and enables the safe discharge of human body static electricity. At the same time, it can detect whether the contact between the human body and the static touch ball is reliable, and sound and light alarms indicate whether the static elimination is completed. The AS6608-YT static discharge alarm can eliminate human body static electricity and also eliminate vehicle body static electricity. It has an integrated design, easy installation, and simple operation.
IIProduct Features
1. Ultra low power consumption design, no need to replace the battery during normal use
2. Touch sensitive, without mechanical moving parts
3. Special topic: Epoxy resin sealing, anti-corrosion, waterproof, and moisture-proof
4 explosion-proof touch ball, safely releases static electricity, and does not produce electric shock when in contact with the human body
5. Sound and light alarm indicates that the contact between the human body and the explosion-proof touch ball is reliable and static electricity has been discharged
6. The grounding wire is independently tested, and the grounding resistance meets the standard to ensure reliable grounding
7. One product, two functions, human body static electricity and vehicle body static electricity can be eliminated simultaneously
IIIElectrical parameters
1. Working power supply: High performance built-in lithium battery
2. Sleep current:<1mA
3. Working current:<5MA
4. Working temperature: -40 ℃~60 ℃
5. Response time:<1s
6. Grounding resistance: ≤ 55 Ω
7. Explosion proof grade: ExiaICT4 Gc
8. Withstand static voltage: ± 20KV
9. Alarm method: Sound and light alarm (>90Db, 30cm straight-line distance measurement)
4mechanical parameters
1. Pole material: 304 stainless steel
2. Pole diameter: Φ 38mm
3. Wall thickness of pole: 1.0mm
4. Product height: 1m
5. Touch ball diameter: Φ 90mm
6. Installation flange wall thickness: 3.0mm
7. Grounding cable length: 3m straight PU cable
8. Electrostatic clamp cable length: 6m spiral PU cable
9. Indicator specifications: 160 * 480mm
5installation diagram