Overview
InterApp pneumatic actuator product model: IA550D F10-F12-F14$r$nIA600D F10-F12-F14$r$nIA650D F12-F14$r$nIA700D F12-F14-F16$r$nIA750D F12-F14-F25$r$nIA800D F16-F25$r$nIA1000D F16-F25-F30
Product Details

InterApp pneumatic actuatorDouble piston toothed bar structure suitable for rotary valves, with meshing and stable output torque (0-8000N. m). The cylinder body material is aluminum alloy or stainless steel. The bottom shaft assembly hole of the pneumatic actuator complies with the ISO5211 standard, and the top and top mounting holes of the air source hole and output shaft comply with the NAMUR standard. The same specifications include double acting and single acting (spring reset), which can be rotated clockwise or counterclockwise according to the valve needs. Install solenoid valves, positioners, limit switches, and manual operating devices according to user needs.
Translate as follows:
InterApp pneumatic actuator is applicable to the double piston rack and pinion structure of rotary valve, with engagement and stable output torque (0-8000N. m). The cylinder body is made of aluminum alloy or stainless steel. The bottom shaft mounting hole of the pneumatic actuator complies with ISO5211 standard, and the air supply hole, the top of the output shaft and the top mounting hole comply with NAMUR standard. The same specification has double acting and single acting (spring return). The direction can be selected according to the valve needs, clockwise or counterclockwise rotation. Install solenoid valve, positioner, limit switch and manual operation device according to the user's needs.

double-acting

IA045D F03-F04

IA050D F03-F04-F05

IA100D F04-F05-F07

IA200D F05-F07

IA250D F05-F07

IA300D F05-F07-F10

IA350D F07-F10

IA400D F07-F10

IA450D F10-F12

IA500D F10-F12

IA550D F10-F12-F14

IA600D F10-F12-F14

IA650D F12-F14

IA700D F12-F14-F16

IA750D F12-F14-F25

IA800D F16-F25

IA1000D F16-F25-F30

single-acting

IA045S(12/22/33) F03-F04

IA050S(6/8/10/12) F03-F04-F05

IA100S(6/8/10/12) F04-F05-F07

IA200S(6/8/10/12) F05-F07

IA250S(6/8/10/12) F05-F07

IA300S(6/8/10/12) F05-F07-F10

IA350S(6/8/10/12) F07-F10

IA400S(6/8/10/12) F07-F10

IA450S(6/8/10/12) F10-F12

IA500S(6/8/10/12) F10-F12

IA550S(6/8/10/12) F10-F12-F14

IA600S(6/8/10/12) F10-F12-F14

IA650S(6/8/10/12) F12-F14

IA700S(6/8/10/12) F12-F14-F16

IA750S(6/8/10/12) F12-F14-F25

IA800S(6/8/10/12) F16-F25

IA1000S(6/8/10/12) F16-F25-F30

InterApp pneumatic actuatorIt is an actuator that uses pneumatic pressure to drive the opening and closing or regulating of valves, also known as a pneumatic actuator or pneumatic device, but generally referred to as a pneumatic head. Pneumatic actuators are sometimes equipped with certain auxiliary devices. Commonly used are valve positioners and handwheel mechanisms. The function of valve positioner is to use feedback principle to improve the performance of the actuator, so that the actuator can achieve accurate positioning according to the control signal of the controller. The function of the handwheel mechanism is to directly operate the control valve to maintain normal production when the control system is shut down, gas is stopped, the controller has no output, or the actuator fails.


InterApp pneumatic actuatorRegarding selection:

Under normal operating conditions, the safety factor considered for double acting actuators is 20% -30%.

Example:

Valve torque=100Nm

Safe torque=100 × (1+30%)=130Nm

Gas source pressure=5Bar

According to the double acting torque table, the minimum specification for selecting a double acting actuator is 130Nm.

Selection of single acting actuators

Under normal working conditions, the safety factor considered for single acting actuators is 30% -50%

For example:

The valve requires a torque of 80N. m

Safe torque=80 (1+30%)=104N. m Air source pressure=5Bar

By comparing the output torque table of the single acting actuator, we can find that the output torque is

Air travel 0 °=308N. m

Air travel 90 °=247N. m

Spring stroke 90 °=181N. m

Spring stroke 0 °=120N. m

All output torques are greater than our requirements.

be careful:

During the process of resetting the spring of a single acting actuator, the ventilation at port B of the actuator does not affect the output torque of the actuator, but instead helps to reset the spring.

638066509906752286836.jpg

The output torque of the spring reset actuator is obtained by multiplying the force (air pressure or spring force) by the force arm. The first condition is that the output torque is obtained by compressing the spring after the air pressure enters the middle chamber, which is called the 'air stroke output torque'. In this case, the air source pressure forces the piston to turn from 0 degrees to 90 degrees, and the spring compression generates a reactive force.