SS Fully Automatic Fuel (Gas) Exemption Steam Generator: Exemption Explanation: This product is designed and developed in accordance with the "Safety Supervision Regulations for Small and Atmospheric Hot Water Boilers", JB/T7985 "Technical Conditions for Small and Atmospheric Hot Water Boilers", and JB/T10393 "Technical Conditions for Electric Heating Boilers". According to the definition of the boiler in Article 99 of the "Regulations on Safety Supervision of Special Equipment", if the volume of this boiler is less than the required 30L volume, it does not belong to the scope of mandatory supervision and inspection of product safety performance stipulated in the "Regulations on the Supervision and Management of Boiler and Pressure Vessel Manufacturing", so it can be exempted from local supervision and inspection. The start and stop of the burner are controlled by pressure, the water pump is controlled by the boiler water level, and the boiler is controlled by a microcomputer with safety measures such as overpressure alarm and pressure safety valve.

Product Details

LSS fully automatic fuel (gas) inspection free steam generator

LSS全自动燃油(气)免检型蒸汽发生器
Product Code:
6201629816
Product Name:
LSS fully automatic fuel (gas) inspection free steam generator
Specifications:

Product Remarks:

Product Category:
LSS type fuel (gas) inspection free steam generator




Product Description
SS Fully Automatic Fuel (Gas) Exemption Steam Generator: Exemption Explanation: This product is designed and developed in accordance with the "Safety Supervision Regulations for Small and Atmospheric Hot Water Boilers", JB/T7985 "Technical Conditions for Small and Atmospheric Hot Water Boilers", and JB/T10393 "Technical Conditions for Electric Heating Boilers". According to the definition of the boiler in Article 99 of the "Regulations on Safety Supervision of Special Equipment", if the volume of this boiler is less than the required 30L volume, it does not belong to the scope of mandatory supervision and inspection of product safety performance stipulated in the "Regulations on the Supervision and Management of Boiler and Pressure Vessel Manufacturing", so it can be exempted from local supervision and inspection. The start and stop of the burner are controlled by pressure, the water pump is controlled by the boiler water level, and the boiler is controlled by a microcomputer with safety measures such as overpressure alarm and pressure safety valve.

Model number

LSS0.03-0.4-Y.Q

LSS0.05-0.4-Y.Q

Project

unit

rated evaporation

t/h

0.03

0.05

Rated working pressure

MPa

0.4

0.4

Saturated vapor temperature

151

151

Fuel

light diesel oil

kg/h

2.1

3.5

natural gas

Nm3/h

2.1

3.5

liquefied gas

Nm3/h

0.9

1.5

city gas

Nm3/h

5.1

8.5

A main steam valve diameter

DN

15

15

B safety valve diameter

DN

20

20

Diameter of drain valve C

DN

20

20

D Inlet diameter

DN

15

15

Chimney diameter

DN

80

80

External dimensions

L

mm

830

880

W

mm

880

890

H

mm

1400

1600

 

Diameter

mm

550

600

weight

kg

220

240