Welcome Customer !

Membership

Help

Tianjin Cable Factory Rubber Cable Factory
Custom manufacturer

Main Products:

smart-city-site>Products

Tianjin Cable Factory Rubber Cable Factory

  • E-mail

    872586202@qq.com

  • Phone

    18232657099

  • Address

    Liu Yanma, Dacheng County, Langfang City, Hebei Province

Contact Now

Low smoke halogen-free cables for coal mines

NegotiableUpdate on 02/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
MYP cable for low smoke halogen-free cables used in coal mines is the abbreviation for mobile rubber sheathed flexible cables used in coal mines. M represents coal mines, Y represents mobile flexible cables, and P represents copper wire shielding.
Product Details

The cables are neatly wound on the cable delivery reel. The cable end is tightly sealed, and the length exposed outside the cable reel meets the requirements of the AC withstand voltage test, Only cables of the same model and specification are allowed to be wound on each cable reel. Prevent severe bending and other mechanical damage. coal mineUse low smoke halogen-free cablesLow smoke halogen-free cables for coal mines

model

name

main purpose

MYJV

Cross linked polyethylene insulated polyvinyl chloride sheathed power cable for coal mines

Power connection laid in underground cable trenches and pipeline fixed locations

MYJV22

Cross linked polyethylene insulated steel tape armored polyvinyl chloride sheathed power cable for coal mines

Power connections installed in fixed locations such as underground cable trenches, pipelines, and direct burial that can withstand mechanical external forces

MYJV32

Cross linked polyethylene insulated fine steel wire armored polyvinyl chloride sheathed power cable for coal mines

Power connections installed in fixed locations such as underground cable trenches, pipelines, direct burial, and slopes that can withstand significant mechanical tension

MYJV42

Cross linked polyethylene insulated thick steel wire armored polyvinyl chloride sheathed power cable for coal mines

Power connections installed in fixed locations such as underground cable trenches, pipelines, direct burial, and slopes that can withstand excessive mechanical tension

1、 Purpose:

This product is rated voltage for coal mines1KVThe fixed laying cables below are suitable for power transmission underground in coal mines.

2、 Usage conditions

The long-term allowable working temperature of the wire core is90The temperature for cable laying shall not be lower than0The allowable bending radius of the cable is15Dd±5%.

model

name

MYJVCross linked polyethylene insulated polyvinyl chloride sheathed power cable for coal mines

MYJV22Cross linked polyethylene insulated steel tape armored polyvinyl chloride sheathed mining power cable

MYJV32Cross linked polyethylene insulated fine steel wire armored polyvinyl chloride sheathed power cable for coal mines

MYJV42Cross linked polyethylene insulated thick steel wire armored polyvinyl chloride sheathed mining power cable

Usage characteristics

Working temperature: conductor high rated working temperature90

Conductor short-circuit temperature: High temperature should not exceed250.

Installation and laying temperature: The temperature for cable installation and laying shall not be lower than0

Laying in the air: ambient temperature40

Laying in soil: ambient temperature25

Scope of Application

This product is suitable for rated power frequency voltage6KV--35kVFor fixed installation in power distribution networks or industrial facilities.

Usage characteristics

Power frequency rated voltageU0/Ufor3.6/6kV26/35kV.

High allowable operating temperature for cable conductors:90.

During a short circuit (not exceeding a certain duration)5s)The high temperature of the cable conductor shall not exceed250.

The ambient temperature during cable laying should not be lower than0.

Cable bending diameter: Three core cable not less than the outer diameter of the cable15Double; Single core cable not less than the outer diameter of the cable20Twice.

Selection of cable rated voltage

The rated voltage of the cable should be suitable for the operating conditions of the cable systemU0/UUmkVexpress.