This gateway is a MODBUS/232/485 to PROFINET gateway, which is a type of serial PROFINET gateway. The gateway on the PROFINET side is a PROFINET IO slave, and on the serial port side, there are two physical interfaces: RS-485 or -232. It supports MODBUS/RTU master or slave protocols (selected by a DIP). When the MODBUS side of this gateway is used as the main station, it can be used for one to many integrated MODBUS/485 or one-to-one integrated MODBUS/232 devices, forming a MODBUS subnet and connecting to PROFINET to meet the technical requirements of PROFINET controller monitoring MODBUS devices. When the gateway MODBUS side serves as a slave station, it can be used to transmit data from other MODBUS master stations (such as PLC/DCS) and their slave stations to the PROFINET controller. The principle of this gateway technology is memory sharing, which does not require programming of the main station PLC/DCS. Simply configure the gateway MODBUS message in the main station configuration (such as STEP7) to achieve the automatic sending function of the gateway MODBUS main station.

Product Details

This gateway is a MODBUS/232/485 to PROFINET gateway, which is a type of serial PROFINET gateway. The gateway on the PROFINET side is a PROFINET IO slave, and on the serial port side, there are two physical interfaces: RS-485 or -232. It supports MODBUS/RTU master or slave protocols (selected by a DIP).
When the MODBUS side of this gateway is used as the main station, it can be used for one to many integrated MODBUS/485 or one-to-one integrated MODBUS/232 devices, forming a MODBUS subnet and connecting to PROFINET to meet the technical requirements of PROFINET controller monitoring MODBUS devices. When the gateway MODBUS side serves as a slave station, it can be used to transmit data from other MODBUS master stations (such as PLC/DCS) and their slave stations to the PROFINET controller. The principle of this gateway technology is memory sharing, which does not require programming of the main station PLC/DCS. Simply configure the gateway MODBUS message in the main station configuration (such as STEP7) to achieve the automatic sending function of the gateway MODBUS main station.

General technical indicators:

1. Power Supply Voltage: Supports dual redundant power supply, wide voltage range: 19.2~28.8VDC
2. 12. Dimensions: (width) 45mm × (height) 125mm × (thickness) 118mm
3. 13. Installation method: 35mm guide rail
4. 14. Protection level: IP20
5. Working temperature: -20 ℃~+55 ℃, working relative humidity: 95% (no condensation)
6. Transportation temperature:- 30℃~+70℃


PROFINET interface technical specifications

1 2XRJ45 Ethernet interface, supporting 100BASE-TX, full duplex communication, MDI/MDIX self detection;
2. Integrated Ethernet switch, making it convenient to form a daisy chain of PROFINET devices;
3. Compliant with PROFINET Class C standards and supports PROFINET version 2.3;
4. So the total input and output data of Slot/subSlot does not exceed 340 bytes;
5. Maximum number of slots that can be inserted: 43;
6. Integrate GSML files.


MODBUS/RTU485/232Technical indicators:

1, SupportMODBUS/RTUagreement,support01H02H03H04H 05H06H0FH10HFunction code;

2Baud rate:300600120024004800960019.2K38.4K57.6KOptional; check bit(8No verification for the position1Stop position8Bit even verification1Stop position8Bit Oddity Verification1Stop position8No verification for the position2stop bit)Optional.

3Bus bridge control words can be flexibly controlledMODBUSMessage transmission: timed transmission (between transmissions)partitionWaiting interval optional), event triggered sending. Can be strictly controlledMODBUSWrite it(05H0FH10H)Command sending, optional: write command enable/Prohibition, data change enable/Prohibited functions;

4The bus bridge status word can comprehensively reflect the gatewayMODBUSCommunication status and serial communication status;

5Maximum input/Output data volume:Input Bytes + Output Bytes 340 BytesMax Input Bytes 252BytesMax Output Bytes 252Bytes

6Bus bridge is a memory sharing gateway that can be configured through the main station without programmingMODBUSMessage configuration and providePROFIBUS I/QarriveMODBUSSite storage area(0134Corresponding relationship of data in the region.




PROFINET Physical Interface

Appearance layout


Product dimensions

Manual Download

GSDML file download