Welcome Customer !

Membership

Help

Shanghai Yifeng Instrument Equipment Co., Ltd
Custom manufacturer

Main Products:

smart-city-site>Products
Product Categories

Shanghai Yifeng Instrument Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 706, Building 5, Xizi International Center, 898 Xiuwen Road, Minhang District, Shanghai (201199)

Contact Now

Paul Gothe flue dioxin&furan sampling system

NegotiableUpdate on 04/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The conventional flue gas sampling system produced by PaulGothe company in Germany can be used for sampling particulate matter inside and outside the flue. Sampling of dioxins and furans only requires the addition of the PCDDPCDF sampling component on top of the particulate matter sampling system

Product Details


Paul Gothe flue dioxin&furan sampling system

Dioxin sampling, automatic constant velocity sampling, made in Germany

The conventional flue gas sampling system produced by PaulGothe company in Germany can be used for sampling particulate matter inside and outside the flue. The system mainly consists of: ① joint sampling head, ② total particulate matter sampling component, ③ drying tower, ④ ITES automatic constant velocity sampler, ⑤ humidity measurement component (optional).


The ITES automatic constant velocity sampler (25.10) includes: an intelligent controller with built-in calibration holes; Sensor box, equipped with interfaces for connecting with pitot tubes and thermocouple sensors; High performance frequency controlled sampling pump with branch valve.


Joint sampling head

Generally, it consists of 2.07 (goose neck connecting tube with different diameter air inlet), 3.01 (front adapter, connecting suction tube and goose neck connecting tube), inner tube (ID 8mm), suction tube (OD 60mm G1/2), pitot tube, and thermocouple.

According to whether it is heated or cooled, it can be divided into three models: non heated (4.51), heated (4.62), and water-cooled (4.72). If the humidity is high and the temperature is high, it is recommended to heat the sampling head; If the temperature is very high, it is recommended to use a water-cooled sampling head.

Material options: T (titanium metal) and A (stainless steel). Available lengths are 500, 1000, 1500, 2000, 2500, and 3000mm.


Image: Non heated joint sampling head


Image: Non heated joint sampling head

Dioxin/furan sampling

Just add the PCDD/PCDF sampling component to the particulate matter sampling system. There are two models of PCDD/PCDF sampling components to choose from. One is a condensation flask+two-stage adsorption tube, and the other is a condensation flask+collection flask+two-stage adsorption tube.

Technical Specifications

Parameter

ITES automatic constant velocity sampler

Compliant with EN, ISO, and VDI standards

The transport box includes: an intelligent controller with built-in calibration holes, a sensor box, connected to pitot tubes and thermocouples, a rotary vane vacuum pump with good airtightness and corrosion resistance, and other connecting wires

Pressure difference: 0.01~10hPa (± 0.02 hPa)

Absolute pressure: 400~1300hPa (± 0.02 hPa output value)

Thermocouple temperature: 0~500 ℃ (± 0.4% output value)

Flow rate calibration hole: 0.5~4m3/h

Operating temperature: -10~60 ℃

Alarm output: 12V

Power supply: 220V

Weight (including pump): 18.9kg

Size: 350 x 280 x 250 mm

drying tower

Material: PVC

Diameter: 160mm

Height: 400mm

Weight: 3.4kg

Temperature: -10~60 ℃

Handheld components (optional)

Stainless steel pipe, used for fixing suction pipes with an outer diameter of 60mm

Length: Approximately 180mm

Weight: 2.3kg

Sound alarm

80dB, Used for exceeding the sampling parameter setting value or triggering an alarm at the end of sampling

Weight: 0.6kg