Pfeiffer Vacuum Gauge Basic Calibration System

NegotiableUpdate on 02/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Pfeiffer Vacuum Gauge Basic Calibration System
Product Details

Pfeiffer Vacuum Gauge Basic Calibration System
In actual production, the measurement accuracy and repeatability of vacuum gauges directly affect the stability of the process and the quality of the product. Therefore, regular calibration of vacuum gauges is particularly important. In response to this application, Pfeiffer, a German company, has launched a vacuum gauge calibration system, which has been widely used in freeze-drying processes in the pharmaceutical industry

Pfeiffer Vacuum Gauge Basic Calibration System
Used for static and dynamic calibration
Calibration range 1.013-10-4 hPa
Easy to operate and flexible
Compliant with ISO/TS 3567 standard
Test up to 3 midsole vacuum gauges
Certified by DAkkS
Accept customer customization

Basic calibration system technical parameters:

model

Basic calibration system
PS A30 105

Basic calibration system
PS A30 106

Basic calibration system
PS A30 107

accuracy

According to different vacuum gauges

Cable length

3 meters

Connect the vacuum gauge

2x DN 16 ISO-KF
2x DN 25 ISO-KF
2x DN 40 ISO-KF

3x DN 16 ISO-KF,
2x DN 25 ISO-KF
1x DN 40 ISO-KF

6x DN 40 ISO-KF

Gas flow rate

5 X10-6-1E3 hPa·l/s

Air inlet

DN 16 ISO-KF

measuring range

1X10-4 – 1E3 hPa

Measurement range max

1X103 hPa

Measurement range min

1 X10-4 hPa

Operation method

Manual

Electricity consumption

230 VA

Front stage pump pumping speed 50 Hz

0.9 m³/h

Nitrogen pumping speed

67 l/s

extreme pressure

< 1X10-7 hPa

weight

27 kg

Data Download

Chinese PDF
English PDF

Chinese PDF
English PDF

Chinese PDF
English PDF


Vacuum gauge calibration method:Based on the comparison of the measured values of the vacuum gauge to be calibrated and the standard vacuum gauge according to ISO/TS 3567 standard The vacuum gauge to be calibrated and the calibrated standard vacuum gauge are connected to a standardized vacuum chamber (according to ISO/TS 3567, specification b) and placed in the same vacuum environment
Provide static calibration and dynamic calibration, which can not only perform static calibration within a measurement range of>1 hPa, but also perform dynamic calibration within a measurement range of<1 hPa

Application of Pfeiffer Basic Calibration System
Freeze drying in the pharmaceutical and food industries
Coating system for optics, glasses, and decorative layers, diffusion barrier layer for PET bottles and packaging films, tool coating
Conduct process monitoring and control to determine the end of the process, in order to form stable quality and minimize scrap rates