Welcome Customer !

Membership

Help

Zhejiang Zhongkong Technology Co., Ltd
Custom manufacturer

Main Products:

smart-city-site>Products

Zhejiang Zhongkong Technology Co., Ltd

  • E-mail

    supcon@supcon.com

  • Phone

  • Address

    No. 309 Liuhe Road, Binjiang District, Hangzhou City

Contact Now

SCTRACE-PM Ultra Low Concentration Smoke and Dust Online Monitoring System

NegotiableUpdate on 11/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

SCTRACE-PM Ultra Low Concentration Smoke Online Monitoring System The SCTRACE-PM series ultra-low concentration smoke online monitoring system is designed for continuous measurement of ultra concentration particulate matter with smoke emissions below 50mg/m ³ from fixed pollution sources. The product has 6 patented technologies and adopts the β - ray absorption method to achieve automatic measurement of ultra-low smoke concentration. It has the characteristics of high measurement accuracy, strong anti-interference ability, and is not affected by changes in particle size, color, chemical composition, or environmental factors such as smoke humidity, temperature, and pressure. Suitable for measuring smoke concentration in fixed pollution source flue gas ducts with low smoke concentration, low flue gas temperature, and high flue gas humidity on site.

Product Details

SCTRACE-PM Ultra Low Concentration Smoke and Dust Online Monitoring System

SCTRACE-PMThe series of ultra-low concentration smoke and dust online monitoring systems are designed for fixed pollution sources with smoke and dust emissions below 50mg/Continuous measurement design for ultra-high concentration particulate matter. The product has 6 patented technologies and adopts the β - ray absorption method to achieve automatic measurement of ultra-low smoke concentration. It has the characteristics of high measurement accuracy, strong anti-interference ability, and is not affected by changes in particle size, color, chemical composition, or environmental factors such as smoke humidity, temperature, and pressure. Suitable for measuring smoke concentration in fixed pollution source flue gas ducts with low smoke concentration, low flue gas temperature, and high flue gas humidity at the "two lows and one high" site.


SCTRACE-PM超低浓度烟尘在线监测系统
SCTRACE-PM超低浓度烟尘在线监测系统
Main Features

performance metrics

Safe and stable C14 radioactive sources are exempt from national standards;

Fully meet the monitoring requirements for ultra-low particulate matter emissions (<5mg/m ³);

The flicker counting detection method has high measurement accuracy;The instrument sampling unit is heated throughout the entire process to preventUltra low concentration particulate matter

Particle condensation;

Power outage protection, automatic recovery of incoming calls, recording real-time and historical data;RS-485Output,4-20mA

Analog output;

Intelligent design, automatic operation, and simple maintenance;


Modular design, intelligent operation, long service life.

measurement methodB

Radiation absorption method+forward light scattering method

measurement range0-10-50mg/

, can be set or customized

measurement periodC14

The radioactive activity is less than 3 7MBq(l00uCi)

zero drift

<±2%F.S

detector

Scintillation counter

Span Drift

<±2%F.S

detection limit0.1mg/

Linear degree

>0.9

output signal

RS-485 output, 4-20mA analog output

ambient temperature

-5 to 55 ° C

ambient humidity

Relative humidity less than 85% RH

Backblowing requirements

>0.5MPa

Power requirements