- Phone
-
Address
Room 1504, Block C2, Yicheng Building, No. 11 Changchun Bridge Road, Wanliu, Haidian District, Beijing
Beijing York Instrument Technology Development Co., Ltd
Room 1504, Block C2, Yicheng Building, No. 11 Changchun Bridge Road, Wanliu, Haidian District, Beijing
Product Overview
AdoptingISOTECH CorporationDry body calibration furnace, precision temperature gauge TTI-7,By using switches 954 and 958, as well as standard probes, and the Chinese fully automatic temperature testing and calibration components developed by York Instruments, you can obtain a fully automatic calibration system for thermocouples and thermal resistors. The system is configured according to user needs to achieve fully automatic verification and improve work efficiency. The Chinese software of the fully automatic calibration system can also use liquid tanks to record thermometers such as glass thermometers that require manual readings, making the measurement range more extensive.
Product Features
By using ISOTECH's dry body calibration furnace, precision temperature gauge TTI-7, toggle switches 954 and 958, and standard probes, coupled with York Instruments' Chinese fully automatic temperature calibration software, you can obtain a fully automatic calibration system for thermocouples and thermal resistors. The system is configured according to user needs to achieve fully automatic verification and unmanned operation.
Product usage instructions
1. System installation
2. System automatic detection
3. Check the standard device
**Step: Open "System Management",**Step by Step:Standard parameter settings,Step Three:Activate automatic calibration
4Data report and certificate management
5Calibration work
“start”Button - Start Experiment; The system starts temperature control, monitors the readings of the standard instrument at regular intervals, and continuously checks whether the temperature meets the constant temperature requirements. Once it reaches the required temperature, the measurement of that temperature point begins and data is recorded. After the measurement is completed, proceed to the next temperature point. The system automatically heats up, cools down, and maintains a constant temperature,Automatic measurement and automatic storage of measurement data. Perform calibration of the following devices at once: PT100 thermistor CU50 thermistor and B, C, D, EJ、K、N、R、 Calibration work for T-type thermocouples. Real time viewing: temperature set point, standard temperature, measurement time, temperature rise and fall curves, and other required data. The system automatically or on-demand saves measurement results or prints fixed format reports. Automated data processing, reporting, and certificate output, with flexible system configuration.
Main parameters of the product
YK2000-C Thermocouple and Thermistor Automatic Calibration System - Basic Configuration (optional upon request)