Welcome Customer !

Membership

Help

Dongfang Flash (Beijing) Optoelectronic Technology Co., Ltd
Custom manufacturer

Main Products:

smart-city-site>Products

Dongfang Flash (Beijing) Optoelectronic Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 1010, Building A, Longyu Center, No.1 Longyu Middle Street, Huilongguan, Changping District, Beijing

Contact Now

Spectral analyzer YOKOGAWA

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

YOKOGAWA's OSA spectrometer is a leading manufacturer in the fields of optical communication and laser testing, with products sold worldwide and a good reputation. Its products not only have leading performance and reliability, but are also convenient to use, and are deeply loved by engineers.

Product Details

YOKOGAWA's OSA spectrometer is a leading manufacturer in the fields of optical communication and laser testing, with products sold worldwide and a good reputation. Its products not only have leading performance and reliability, but are also convenient to use, and are deeply loved by engineers.

model

AQ6370D

AQ6360

AQ6373B

AQ6374

AQ6375E

AQ6376E

AQ6377

bandwidth

optical communication

optical communication

VIS

VISAnd optical communication

exNIR

MWIR

MWIR

Wavelength Range(nm

600-1700

1200-1650

350-1200

350-1750

1000-2500

1500-3400

1900-5500

wavelength accuracy

±0.1(Full wavelength range)±0.04(1450~1520nm) ±0.01(1520~1580nm)

±0.02(1580~1620nm

±0.1(Full wavelength range)±0.02(1520~1580nm) ±0.04(1580~1620nm)

±0.2(Full wavelength range) ±0.05(633nm)

±0.2(Full wavelength range)±0.05(633nm) ±0.05(1523nm)

±0.5(Full wavelength range)

±0.5(Full wavelength range)

±0.5(Full wavelength range)

Wavelength resolution setting(nm,minimum)

0.02

0.1

0.01

0.05

0.05

0.1

0.2

Wavelength resolution setting(nm,maximum)

2

2

10

10

2

2

5

Measure power range(dBm,Minimum)

−60(600~1000nm) −80(1000~1300nm) −90(1300~1620nm)

−80(1300~1620nm)

−60(400~500nmType.)−80(500~1000nmType.)−60(1000~1100nmType.

−70(400~900nm)−80(900~1600nm)

−62(1000~1500nm)−67(1500~1800nm,

−70(1800~2200nm)

-65(1500~2200nm)−55(2200~3200nm)−50(3200~3400nm)

−40(1900~2200nmType.)−50(2200~2900nmType.)−60(2900~4500nmType.)

Measure power range(dBm,Maximum)

+20

+20

+10(400~550nm)+20(550~1100nm)

+10(400~550nm)+20(550~1700nm)

+20

+13

+13

Power accuracy(dB)

±0.4

±0.5

±1.0

±1.0

±1.0

±1.0

±2.0

dynamic range(dB)

50(±0.1nmRES:0.02nmType.)

78(±1.0nmRES:0.05nmType.)

40(±0.2nmRES:0.1nm)

55(±0.4nmRES:0.1nm)

60(±0.5nmRES:0.02nm)

60(±1.0nmRES:0.05nm)

45(±0.4nmRES:0.05nm)

55(±0.8nmRES:0.05nm)

40(±1.0nmRES:0.1nm)

55(±2.0nmRES:0.1nm)

50(±5.0nmRES:0.2nmType.)

Built in cut-off filter for high-order diffracted light

/

/

yes

yes

yes

yes

yes

Light source for wavelength calibration

yes

yes

/

yes

yes

yes

yes