Table Drop Tester $r $n I. Core Functions and Scope of Application $r $n1. Test Purpose $r $n To evaluate the structural stability, connector strength, and durability of table furniture under simulated drop impact, ensuring its ability to resist accidental drops in practical use, and ensuring safety and functionality.
Product Details

table categoryDrop tester

1、 Core functions andScope of Application

1. Objective of the test

Evaluate the structural stability, connector strength, and durability of table furniture under simulated drop impact, ensuring its ability to resist accidental drops in practical use, and guaranteeing safety and functionality.

2. Scope of Application

Fixed, foldable, or movable desk furniture suitable for home, office, and public use, including different materials and structural types.

3. Test equipment

Drop testing machine:

Adjustable range of drop height:300mm~1500mmSet according to product weight classification (such as ≤10kgset300mm10~20kgset500mm>20kgset800mm).

Material of falling surface: concrete or steel rigid plane, surface flatness ≤2mm/m², Ensure uniformity of impact.

Release mechanism: Electromagnetic control or pneumatic release, allowing the sample to fall freely without rotation, avoiding human interference.

Data acquisition system: accelerometer (range ≥)50gAccuracy ±5%)High speed camera (frame rate ≥)1000fps)Record the impact dynamics and structural response.

Auxiliary tool: Level (accuracy ±)0.5°), steel tape measure (accuracy ±)1mm)Torque wrench (accuracy ±)3%).

4. Sample preparation

Quantity: At least for each type of product3One sample to ensure representativeness.

State adjustment: Sample at temperature(23±2)℃, relative humidity(50±5%Preprocessing in the environment24Eliminate the influence of environmental factors within hours.

Load simulation: Apply static loads according to standard requirements (such as desk loading)50kgTable loading30kg)Placing drawers or cabinet doors5kgSimulate the usage status of the counterweight.

2、 Key pointparameter

Parameters

Requirement

control system

PLCcontrol system

operating interface

colorful7Inch touch screen, switching between Chinese and English

printer

Embedded micro thermal printer with printing paper1roll

Falling height

According to product weight classification:
-10kg300mm
- 10~20kg500mm
- >20kg800mm

Falling direction

Corner, edge, and surface drop in three directions, repeating in each direction3The second (total)9Next time).

Impact velocity

By calculating the height, the formula is:v = \\sqrt {2gh}v =2ghg=9.8m/s²g=9.8m/s2).

Impact energy

Calculation formula:E=mghE=mghmmFor the quality of the sample,hhFor the height of the fall.

3、 TestingstepAnd explanation

Positioning the specimen: Place the loaded specimen at the center of the drop surface, ensuring that the levelness is ≤1°.

Select drop point:

Corner drop: Intersection point of the diagonal of the specimen.

Edge drop: the midpoint of the long edge.

Face Drop: Geometric Center of Desktop.

Release the sample: achieve free fall through electromagnetic or pneumatic mechanisms, and record the data of the moment of impact.

Inspection and recording:

Visually inspect for structural deformation, loose connections, coating detachment, etc.

Functional testing: Check if drawer slides, folding mechanisms, etc. are functioning properly.

Repeat experiment: Complete in order of direction9Repeated drops and cumulative damage.

Qualification assessment

Structural integrity: No fracture, permanent deformation, or detachment of connectors.

Function retention: drawers, doors, and other components can be opened and closed normally, and the folding mechanism is not stuck.

Safety: No sharp edges or fragments generated.

Data recording and reporting

Required fields: Drop height, direction, frequency, specimen status, damage mode.

Optional: Impact acceleration curve, high-speed video screenshot, torque change data.

Precautions

Before the experiment, the equipment needs to be calibrated to ensure that the drop height error is ≤±5mm.

When conducting multiple sample tests, intervals are required10Minutes to avoid equipment overheating.

Special structures (such as glass tabletops) require additional protective measures to prevent debris from splashing.

fourexecuteStandards and Applicable Scenarios

Compliant with standards:

strictly followGB/T 10357.1-2024

Typical applications:

Batch quality inspection of production line; Third party laboratory certification.

5、 Configuration List

host1Taiwan;

test software1Set;

Instruction Manual1copy;

Certificate of Conformity1copy;

Warranty Card1copy;

Delivery Receipt1copy;

nameplate1block;

power cord1root;

wrench1set;

Several brochures;

table categoryDrop tester