The new DIL offers a dual furnace system, which can expand the testing temperature range to -180 ℃ If the temperature requirement is relatively simple at 2000 ℃, the testing efficiency can be greatly improved by using dual furnace bodies.
Product Details

1、 Product Introduction:

The new DIL 402 Expedias Select&Supreme thermal expansion meter from Nike integrates cutting-edge technology in the field of thermal expansion measurement, designed for professional level applications in a wide range of fields. All models in the DIL Expedia series are based on the revolutionary NanoEye measurement system, reaching new heights in both measurement range and accuracy.
This instrument is the first horizontal expansion instrument on the market to support modulation force (oscillatory load), which bridges the gap between thermal expansion instruments and thermomechanical analyzers (TMA) and dynamic thermomechanical analyzers (DMA).
The Supreme version has comprehensive configuration and powerful features, while the Select version can be flexibly upgraded. These two versions are tailored for research and development, as well as specialized industrial applications.

Instrument characteristics
Highest flexibility and sample efficiency
The instrument has a dual furnace structure and can simultaneously install two different furnaces, covering a wide temperature range from 180 ℃ to 2000 ℃. Another configuration plan is to equip two identical furnace bodies for alternating use, combined with a dual rod sample holder for testing in dual sample mode, which can greatly shorten the sampling cycle and improve the efficiency of instrument use.
Expedia Select/Supreme offers a wide range of configuration options: single/double furnace, manual/motor-driven furnace operation, single/double sample holder, tubular/rod-shaped sample holder, and more. The rich configuration is designed to adapt to various application scenarios.

Automatic length testing and MultiTouch
Traditional thermal expansion instruments typically use calipers to measure the original length of samples, which may increase the uncertainty of measurement results, especially for soft samples. DIL 402 Expedias can automatically measure the initial length of the sample under conditions equivalent to the test itself (contact position of the top rod, contact force) before the test begins.
For reliable thermal expansion measurement, it is crucial for the sample to have a stable placement position within the sample holder. The MultiTouch function of DIL 402 Expedias uses a unique tail type top sample operation to automatically adjust the placement position of the sample to the best.
The thermocouple position of DIL 402 Expedias can be flexibly adjusted to accommodate different sample lengths. By guiding the rod, the thermocouple can be adjusted to a suitable position that matches the length of the sample, without the need to bend the thermocouple.

Support 3 external gas connections; Can be connected to the analysis of escaping gases
If a three-way mass flow controller (MFC, optional) is used, the gas path inside the instrument is separated: the protective gas first passes through the measurement unit and then enters the sample chamber, while the blowing gas (two-way) directly enters the sample chamber, and both the protective gas and the blowing gas are discharged through the outlet of the furnace body.
The DIL 402 Expedia instrument has a vacuum sealed design and is equipped with a SiC furnace body that is very suitable for use in conjunction with QMS or FTIR through capillary tubes. During the testing process, it conducts in-depth research and analysis on impurities, additives, organic binders, and decomposition products that escape.

2、 DIL 402 Expedias Select/Supreme - Technical Parameters
Temperature range: -180 1600 ° C (conventional, multiple furnace options available); The ultra-high temperature version can reach up to 2800 ℃
Number of furnaces: single furnace or double furnace (different configurations)
Sample quantity: single sample, or dual sample/differential system (different configurations)
Heating rate: 0.001 50 K/min or 100 K/min (different furnace bodies)
Measurement System: NanoEye
Sample holder: fused silica or alumina, freely replaceable.
Temperature accuracy: 1 K
Temperature accuracy: 0.1 K
m. CTE (Coefficient of Linear Expansion) repeatability: 10-8 1/K
Measurement range: ± 10000 μ m/± 25000 μ m
Resolution: 0.1 nm/1 nm (full range)
Sample length: 0 52mm (automatic sample length measurement)
Load force mode: constant force, linear force, step force; Modulation force (optional)
Load force range: 10 mN... 3N
Gas control: Comes standard with 1 channel, optional with 3 channels or MFC (Mass Flow Meter)
Atmosphere: Inert, oxidizing, reducing, vacuum
Vacuum sealed design, optional fully automatic vacuum system
Optional cooling system: Vortex, liquid nitrogen
OTS ® Oxygen adsorption system (optional)

3、 DIL 402 Expedias Select/Supreme - Software Features
Unique Proteus ® The 7-expansion instrument software provides everything users need: smooth operation, reliable results, fast and efficient. It provides rich features while also having a clear user interface. In addition, due to its intuitiveness, it is also very easy to learn.
However, this is far from everything. Even the most experienced operator will be impressed by the numerous additional features that this software can provide - especially density measurement, c-DTA ® Patent technology and innovative spectrum retrieval and recognition function Identify.
Proteus ® List of Special Software Features
(For DIL 402 Expedias Select and Supreme)

Softening point detection
Software controlled force adjustment (including linear force, constant force, oblique force, step force)
Modulation force
Density measurement
C-DTA for temperature correction and detection of thermal effects ® Function
Rate controlled sintering RCS
Curve recognition, identifying unknown Δ L/L0 curves through database comparison
Density measurement
This plugin can measure the continuous changes in sample density and can be applied to solids, liquids, melts, viscous samples (such as coatings), as well as to calculate the volumetric expansion of anisotropic materials.
c-DTA ® patent technology
c-DTA ® The signal can analyze the heat absorption and release effects while analyzing length changes. It can also be used for temperature correction.
Patent number: DE102013100686
advanced software
(Extended analysis of measurement data. Optional)

Dynamics software
Peak separation software (used for processing DIL differential signals)
Curve recognition Identify
Identify is a unique DIL curve recognition technology in the industry, which includes search software and hundreds of reference data from multiple built-in databases, covering the fields of ceramics, inorganic materials, metals, alloys, polymers, and organic compounds. In addition to the database provided by Nike, customers can also create their own database and share it with other users through the internal network.
By using curve recognition technology, matching and searching in the database based on the absolute expansion, shape, and slope of the test curve, unknown samples can be identified and analyzed. A known sample can also be used as a standard to compare and evaluate a batch of unknown samples for quality control. Finally, all test data can be stored in a large database for subsequent sample identification or quality control.
Advantages of Curve Identification
With just one click of the mouse, Indentify can provide the required information:

Identify unknown measurement curves
Quality control is achieved by comparing the test curve with the standard curve in the database
Archive functionality for existing entries in current testing and databases
Can easily add existing tests to the database

4、 DIL 402 Expedias Select/Supreme - Related attachments
Optional OTS accessory to ensure a pure blowing atmosphere in the system
Multiple vacuum pumps can ensure a pure atmosphere in the system or be tested under vacuum conditions.
Automatic provision of nitrogen protection during low-temperature furnace cooling
Low temperature furnace air cooling system
QMS 403 A ë olos ® Quartz capillary tube connecting accessories and heating adapter for joint use
Sample thermocouple protective sleeve
Protective container for easily contaminated samples
Sample preparation equipment