PfeifferTurbomolecular pumpHiPace 30
Shanghai Bodong Germany PfeifferTurbomolecular pumpHiPace 30.Molecular pumpCompact design, height of 12 centimeters, weight of only 2kg, easy to move, pumping speed of 30L/S. Especially suitable for small chamber vacuum pumping The unique rotor design ensures ultra-low vibration of the molecular pump Compression ratio for nitrogen gas up to>1011Up to 3x10 compression ratio for hydrogen gas7. High gas throughput and high compression ratio make it a star product among similar products!
Turbomolecular pumpHiPace 30 Technical Parameters
|
model |
HiPace ® 30, TC 110 |
HiPace ® 30, TC 110 |
HiPace ® 30, TC 110, |
||
|
Molecular pump image |
|
|
|
||
|
Composite bearings |
Ceramic ball bearings |
||||
|
Ar compression ratio |
> 1 X1011 |
||||
|
H2Compression ratio |
3 X105 |
||||
|
He compression ratio |
3 X107 |
||||
|
N2 Compression ratio |
> 1 X1011 |
||||
|
Standard cooling |
convection |
||||
|
Optional cooling |
Air-cooled, water-cooled |
||||
|
Cooling water consumption |
75 l/h |
||||
|
Cooling water temperature |
5-25 °C |
||||
|
Electronic Drive |
TC 110 |
||||
|
Intake flange |
DN 63 ISO-K |
DN 63 CF-F |
DN 40 ISO-KF |
||
|
Exhaust flange |
DN 16 ISO-KF, G ¼" |
||||
|
Maximum pre vacuum, N2 |
24 hPa |
||||
|
Gas flow rate at full speed, Ar |
0.22 hPa l/s |
||||
|
Gas flow rate at full speed, H2 |
10 hPa l/s |
||||
|
Gas flow rate at full speed, He |
1.84 hPa l/s |
||||
|
Gas flow rate at full speed, N2 |
0.66 hPa l/s |
||||
|
communication interface |
RS-485, Remote |
||||
|
Installation method |
Install at any position |
||||
|
Operating voltage |
24 (± 5 %) V DC |
||||
|
Maximum allowable magnetic field |
3 mT |
||||
|
Protection type |
IP 54 |
IP 54 |
IP 30 |
||
|
Extraction speed Ar |
32 l/s |
32 l/s |
20 l/s |
||
|
Extraction speed H2 |
20 l/s |
20 l/s |
19 l/s |
||
|
Extraction speed He |
24 l/s |
24 l/s |
23 l/s |
||
|
Drawing speed N2 |
32 l/s |
32 l/s |
22 l/s |
||
|
Speed ± 2% |
90,000 rpm |
||||
|
Start time |
1.7 min |
||||
|
Extreme vacuum |
< 1X10-7hPa |
< 5X10-10hPa |
< 1X10-7hPa |
||
|
Air release interface |
G 1/8" |
||||
|
weight |
2 kg |
3.2 kg |
2 kg |
||
|
Molecular Pump Data Download |
Chinese PDF |
Chinese PDF |
Chinese PDF |
||
Pfeiffer, GermanyTurbomolecular pumpHiPace 30 application areas
Desktop electron microscope vacuum small mass spectrometry system vacuum mobile gas analysis system vacuum helium leak detection system vacuum
Pfeiffer, GermanyTurbomolecular pumpHiPace 30 Draw Speed Comparison Chart



Turbo molecular pump HiPace30 Currently available models for sale:
Molecular pump HiPace 30 TC 110 DN 63 ISO-K
Molecular pump HiPace 30 TC 110 DN 63 CF
Molecular pump HiPace 30 TC 110 DN 40 ISO-KF
Recommendations for other popular molecular pumps from Pufa
|
Molecular pump HiPace 10 |
Molecular pump HiPace 60 P |
Molecular pump HiPace 80 |
PfeifferTurbomolecular pumpThe pumping speed range is 10 to 2700 L/S, with a maximum speed of 90000 rpm and a maximum ultimate vacuum of 1E-11 mbar. It has a higher compression ratio for small molecule gases, and practical experience has shown that PfeifferTurbomolecular pumpThe running time can reach 100000 hours!Pu Fa Molecular PumpProvide composite bearingsMolecular pumpAnd five axis full maglevMolecular pumpTwo major series meet different applications, recommended for pairingPfeiffer rotary vane pumpandDry pumpShared useRecommended Typical Applications of Molecular Pumps>>
If you need further understandingMolecular pumpFor detailed information, please refer to the following contact information
Shanghai Bodong: Miss Ye Taiwan Bodong: Miss Wang
T: +86-21-5046-3511 ext 109 T: +886-3-567-9508 ext 161
F: +86-21-5046-1490 F: +886-3-567-0049
M: +86 1391-883-7267 M: +886-939-653-958
ec@hakuto-vacuum.cn ec@hakuto.com.tw