Ultrasonic heat meter*********

NegotiableUpdate on 06/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

1、 Overview: Ultrasonic calorimeter is an instrument used to measure and display the heat released (absorbed) by a heat (cold) liquid flowing through a heat and cold exchange system. The ultrasonic heat meter consists of a controller and a base meter. The controller consists of a flow sensor, a microprocessor, and a paired temperature sensor. The microprocessor obtains flow signals through flow sensors and base meters, obtains outlet and inlet water temperature signals from temperature sensors, and calculates the energy exchanged by the system based on the standard heat calculation formula. Users can choose an ultrasonic heat meter with M-BUS communication function, which can

Product Details

>

1、 Overview

Ultrasonic calorimeter is an instrument used to measure and display the heat released (absorbed) by a heat (cold) liquid flowing through a heat and cold exchange system.

The ultrasonic heat meter consists of a controller and a base meter. The controller consists of a flow sensor, a microprocessor, and a paired temperature sensor. The microprocessor obtains flow signals through flow sensors and base meters, obtains outlet and inlet water temperature signals from temperature sensors, and calculates the energy exchanged by the system based on the standard heat calculation formula.

Users can choose an ultrasonic heat meter with M-BUS communication function, which can communicate with other devices through the M-BUS bus to form a remote meter reading management system; Ultrasonic heat meters with wireless communication capabilities can also be used, which can communicate through PDA or other wireless devices to form a remote meter reading management system; The management department can access the data in the table at any time to facilitate the control of users' heat consumption.

The ultrasonic heat meter is a high-performance, low-power electronic heat meter developed and designed with reference to European standards EN1434 and OIML-R75 international regulations. Complies with the CJ128-2007 "Heat Meter" product standard issued by the Ministry of Construction of China. M-BUS or wireless remote communication protocol complies with CJ/T128-2004.

2、 Characteristics

1. Low voltage alarm.

2. Automatic data correction technology.

3. Temperature sensor open circuit and short circuit alarm.

4. High definition wide temperature LCD display.

5. The flow is calibrated in 8 segments with high accuracy.

6. Ultra low power consumption (static power consumption less than 7uA).

7. The pipe section is a straight through integrated structure manufactured using forging technology.

8. The measuring mechanism has no moving parts, no wear and tear, and the measurement accuracy is not affected by the service life.

9. Equipped with photoelectric interface, communication distance of more than 2 meters, and infrared tools can be used to achieve meter reading.

10. Installation is extremely convenient, installed horizontally or vertically.

11. M-BUS or wireless remote communication can be used, with a long communication distance.

3、 Usage method

1. When there is flow, the heat meter will cycle and display:

Accumulated heat:accumulateXXX kWh

Accumulated traffic:accumulateXXX. XX meq \ \ o (\ \ s \ up 5 (3)\ \\ do 2()) 3

Instantaneous flow rate:instantaneousXxx.xxx m3/h

Temperature: XX. XEntrance and exitXX.X ℃

Temperature difference:Temperature differencex.x ℃

Accumulated working time:accumulateXXX h

2. When there is no flow, the heat meter often displays:

Accumulated heat:accumulateXXX kWh

3. M-bus communication

Users can choose M-bus communication function ultrasonic heat meters, which can be remotely read with collectors, concentrators, management software, etc. The collector has a carrying capacity of no less than 64 heat meters. Before use, an address file is established on the upper computer, and the table address is set at the factory (the 12 digit code of the ultrasonic heat meter production serial number ID). After the centralized meter reading system composed of the heat meter, concentrator, collector, upper computer, etc. is completed, the management department can read the data in the table at any time.

Note: 1. In a system, the address of the heat meter cannot be duplicated.

2. The M-BUS communication line of the heat meter does not distinguish between positive and negative poles, and can be connected to the collector interface through the M-BUS bus.

4. Data query

The ultrasonic heat meter stores the monthly usage heat and flow rate for the past 18 months. Gently shake the magnet near the production serial number of the ultrasonic heat meter, and the heat meter will display:

Version number: No.XXXX

Year, Month, Day: XX-XX-XX

Hour, minute, second: XX.XX.XX

Current time year and month:

XX-XXCurrent monthly heat usage:accumulate

XXX kWhCurrent monthly traffic usage:accumulate

XXX. XX meq \ \ o (\ \ s \ up 5 (3)\ \\ do 2()) 3

Last month year and month: XX-XXLast month's heat usage:accumulate

XXX kWhLast month's traffic usage:accumulate

XXX. XX meq \ \ o (\ \ s \ up 5 (3)\ \\ do 2()) 3

Last February Time Year/Month: XX-XXHeat usage in February:accumulate

XXX kWhLast February's usage of data:accumulate

XXX. XX meq \ \ o (\ \ s \ up 5 (3)\ \\ do 2()) 3

...... ......

Last 17 months Year and Month: XX-XXLast month's heat usage:accumulate

XXX kWhLast month's traffic usage:accumulate

XXX. XX meq \ \ o (\ \ s \ up 5 (3)\ \\ do 2()) 3

After 18 months of monthly heat usage, the monthly flow rate is displayed in a cyclic manner and enters a normal state for display.

4、 Work status

Due to the different resolution requirements and normal working conditions required for ultrasonic heat meters during calibration, our company's ultrasonic heat meters have two working states: calibration state and normal working state. The difference between the two working states is the display resolution.

The ultrasonic heat meter can be entered into the inspection state using the "inspection state startup card". Gently shake the left end of the transparent window of the "Check Status Start Card" against the production serial number of the ultrasonic heat meter, align the "Check Status Start Card" with the infrared interface of the ultrasonic heat meter, press the button, and the communication is successful. The heat meter enters the check status, and automatically enters the normal status after 4096S.

The specific list of differences is as follows:

project

Normal working condition

Checklist status

Small display unit for heat:

1kWh

0.001kWh

* * * * Small display unit of accumulated traffic

0.01meq \ \ o (\ \ \ \ up 5 (3)\ \s\\do

2 ()) 3

0.00001 meq \ \ o (\ \ s \ up 5 (3)\ \s\\do

2 ()) 3

5、 Technical parameters3flow sensor

Nominal diameter3Common traffic (m)

/h)3***Small traffic (m

40

10

0.2

20

50

15

0.6

30

65

25

1

50

80

40

1.6

80

100

60

2.4

120

125

100

4

200

150

150

6

300

200

250

10

500

250

400

16

800

300

600

24

1200

/h)

***Large traffic (m

/h)

***Small display traffic

0.1meq \ \ o (\ \ \ \ up 5 (3)\ \\ do 2()) 3 (when in use) 0.00001meq

\\O (\ \ s \ up 5 (3)\ \\ do 2()) 3 (during calibration)

***Small display heat

1kWh (during use) 0.001kWh (during calibration)

temperature sensor

***Small temperature difference

1 or 3 ℃

***Large temperature difference

90℃

***Small display temperature

0.1℃

Static working current

< 7uA

Battery life

>5 years9 LCD display number of digits

8 digits

***Accumulated working hours94.2x10

Hours (When working hours>hours, only the last 8 significant digits of * * * can be displayed)

***Large cumulative traffic

4.2x10

Meq \ \ o (\ \ s \ up 5 (3)\ \\ \ do 2()) 3 (cumulative traffic>9999999.99 meq \ \ o (\ \ \ up 5 (3)\ \When displayed at 3 o'clock, only the last 8 significant digits of * * * can be displayed

accuracy class

Level II or III

pressure resistance

1.6MPa

pressure loss

≤ 0.025 MPa

6、 Error handling

Error symbol

meaning

Reason for error

processing method

ERR5

ERR6

ERR7

ERR8

ERR9

Temperature measurement error

PT1000 disconnection, open circuit, etc

Check hardware

7、 Installation

1. Installation of the entire meter:

(1) Suggest installing a filter before the ultrasonic heat meter.

(2) It is recommended to install a valve before the filter to facilitate maintenance and cleaning of the filter.

(3) Before installation, please flush the pipeline to prevent any debris such as hemp fibers, sand, and stones inside.

(4) Do not pull, rotate, or collide with the internal components of the pipeline during installation to avoid damaging the body.


(5) During installation, sufficient maintenance space must be reserved and installed in the direction of the flow indication arrow on the pipe section.


(6) The ultrasonic heat meter is installed horizontally or vertically at the inlet of the pipeline, but when installed horizontally, the two transducers should be on the same horizontal plane. When installed vertically, the ultrasonic heat meter must be installed on a straight pipeline with upward water flow.

(7) When connecting the body to the pipeline, do not apply too much force to avoid damaging the sealing gasket and causing water leakage.

(8) The heat meter should be handled with care and not bumped during transportation; Storage in strong electromagnetic fields should be avoided.

DN40 caliber


DN50、 65 caliber

DN80-300 caliber

Figure 1 Schematic diagram of overall installation of ultrasonic heat meter

Attention: During installation, install the temperature sensor connector labeled with the inlet probe in the ultrasonic waveform table.

2. Installation of temperature probe:

A. Installation method of DN40-65 caliber heat meter temperature probe:

Figure 2

(1) The size of the probe protection tube is shown in Figure 2


(2) Drill a hole vertically downwards at an appropriate position in the outlet pipeline (hole diameter 15mm);

(3) After drilling the installation hole, place the probe protection tube in the corresponding position of the installation hole and weld it at the "welding point";

(4) After the welding is completed and the welding joint cools down, screw the outlet probe into the probe protection tube and screw it to the bottom;

(5) Seal the probe and probe protection tube with lead.

B. Installation method of DN80-300 caliber heat meter temperature probe:

(1) Select the probe, protective tube, and welding base according to the pipe diameter, refer to the table below.

Figure 3

Unit: mm

pipe diameter

Probe length L1

Protection Manager L2

105

85

20

18

28

Welding base

140

120

Long L3

Inner diameter D1

Outer diameter D2

DN80~150

DN200~300

(2) Drill a hole vertically downwards at an appropriate position in the outlet pipeline (hole diameter 18mm);

(3) After drilling the installation hole, weld the base to the corresponding position of the installation hole;


(4) After the welding is completed and the welding joint cools down, cover the protective tube of the outlet probe with a sealed copper gasket, wrap the outer wire with adhesive tape, and screw it into the corresponding outlet pipe base, making sure to tighten it;


(5) Insert the probe into the bottom of the protective tube and secure it tightly with fixing screws.

(6) Seal the probe and probe protection tube with lead.

Note: 1. When leaving the factory, the inlet probe protection tube has been installed on the body, only the outlet probe needs to be installed.

2. When welding the base, the end with inner wire should face upwards, and the end without wire should be welded.

8、 Dimensions DN40 caliber dimensions

Outline dimension drawing of base table with dimensions ranging from 50 to 200

40

200

100

135

Caliber (mm)

50

200

165

190

Length L (mm)

65

200

185

210

Width W (mm)

80

225

200

220

Height H (mm)

100

250

220

245

Connection method

125

250

250

260

Thread G2B

150

300

285

300

Flange ¢ 125-4 × ¢ 19

200

350

340

365

Flange ¢ 145-4 × ¢ 19

250

450

405

430

Flange ¢ 160-8 × ¢ 19

300

500

460

485

Flange ¢ 180-8 × ¢ 19

Flange ¢ 210-8 × ¢ 19

Flange ¢ 240-8 × ¢ 22

Flange ¢ 295-12 × ¢ 22

Flange ¢ 355-12 × ¢ 26

Flange ¢ 410-12 × ¢ 26

Note: The width in the above table is the self width of the ultrasonic base surface, and the width of the finished surface may be about 20-30mm wider than the base surface due to assembly differences.

9、 Supporting supply

1. One ultrasonic heat meter

2. 1 pair of temperature sensors