Vacuum low-temperature blackbody radiation source

NegotiableUpdate on 04/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Vacuum low-temperature blackbody radiation source
Product Details

RussiaVNIIOFIThe vacuum low-temperature blackbody radiation source series was developed by the All Russian Institute of Optical Physics Measurement, a technical control and metrology department of the Russian Federation. At present, it has been applied in multiple national metrology institutes and has received widespread praise from users.

The vacuum low-temperature blackbody radiation source series has high stability and a wide range of models, with temperatures as low as 80K. For specific models, please contact York Company.


Product Features

  • ★ Large caliber: 100mm diameter
  • ★ High stability performance
  • ★ High emissivity: 0.997
  • Under vacuum conditions, the temperature can reach -60 degrees Celsius°C

Product parameters

model

BB100-V1

temperature range

-60°C~90 °C- Vacuum environment

(-50~90)°C- Inert gas or dry gas blowing

Opening aperture

100mm

Diameter of cavity

120mm

Radiation cavity material

copper

Temperature gradient along the cavity

≤ ± 0.1°C

Temperature instability

± 0.05°C

temperature control

Through an external constant temperature cycler

effective emissivity

0.997(1.5~15μm)

All temperature sensors

5 platinum resistors (100 Ω)

Temperature measurement based on KEITHLEY 2000 (or Agilent 34660) digital meter and multi-channel amplifier

5 calibrated PRT100 temperature sensors are used for temperature monitoring (2 placed along the cavity and 3 placed at the bottom of the cavity).




Low temperature blackbody radiation source

model

BB80/350

temperature range

220—350K

Additional set points

313K

Working aperture

350mm

spectral range

2.5—15μm

emissivity

0.96±0.02

Uncertainty @ 280-300K

±0.1K

Repeatability @ 300K

0.5K

10 minute stability

5K

Continuous running time

8 hours

work environment

indoors

Dry nitrogen atmosphere

Standard Pressure

Environmental temperature: 0-30°C

vacuum chamber

P=10-510-8Torr

Environmental temperature: 77K