Overview
The LA-M20K three-phase power lightning protection module has a large lightning current discharge capability and is suitable for various levels of protection in low-voltage distribution systems. Multiple combination methods can be selected according to different distribution systems (TT/TN/IT). Which is a good three-phase power lightning protection module
Product Details

Product Features:

◆ High energy surge protection
◆ Built in instantaneous overcurrent circuit breaker device
◆ Pluggable and replaceable lightning protection module
◆ Failure detection indication
Single module discharge current 40KA
◆ Standard modular installation
◆ Built in overheat circuit breaker device
◆ NS level reaction speed
◆ Plug and unplug foolproof design(Which is a good lightning protection module for three-phase power supply

Product installation:

1. SPD is installed at the power input end of the building's main distribution cabinet or distribution box, equipped with 35mm electrical rails. Before installation, the power must be cut off and live operation is strictly prohibited.
2. During installation, SPD should be installed in conjunction with fuses of the corresponding specifications. Please connect according to the installation diagram, where L1, L2, and L3 phase wires, N is the neutral wire, and PE is the ground wire. Do not connect them incorrectly. After installation, check if the working status is normal.
3. During use, the lightning protection module should be regularly inspected and the status of the fault display window should be checked. When the fault display window is red, it indicates that the lightning protection module has malfunctioned and should be repaired or replaced in a timely manner. (Which is a good lightning protection module for three-phase power supply
4. Suitable for indoor operation, if installed outdoors, a waterproof casing must be added.
5. All wiring must be securely and reliably electrically connected. SPD connection wire: BVR ≥ 4mm2, grounding wire: BVR ≥ 6mm2, the lead length should be less than 1m and the shorter the better.
6. Lightning protection grounding should comply with lightning protection regulations, with grounding wires as thick and short as possible and grounding resistance less than 4 Ω.

LA-M20KInstallation Diagram