Welcome Customer !

Membership

Help

Yangzhou Enyuan Electric Co., Ltd
Custom manufacturer

Main Products:

smart-city-site>Products

Yangzhou Enyuan Electric Co., Ltd

  • E-mail

    1714323997@qq.com

  • Phone

    13952561741

  • Address

    Liubao Industrial Park, Baoying County, Yangzhou City, Jiangsu Province

Contact Now

YSB3060A AC/DC instrument calibrator

NegotiableUpdate on 03/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
YSB3060A AC/DC instrument calibrator is mainly used for testing and calibration of reactive power compensation controllers, power data collectors, on-site energy meter calibrators, power parameter testers, voltage monitors, distribution load monitors, multifunctional power instruments, load management terminals, voltage and current loss timers, distribution automation terminals and other instruments and equipment; Testing and calibration of digital electrical measuring instruments such as energy meters, voltmeters, ammeters, phase meters, frequency meters, power meters, and power factor meters, as well as testing and calibration of electrical quantity sensors such as instrument voltage transformers, current transformers, clamp current transformers, etc
Product Details

YSB3060AAC/DC instrument calibratorMainly used for testing and calibration of reactive power compensation controllers, power data collectors, on-site calibration instruments for electric energy meters, power parameter testers, voltage monitors, distribution load monitors, multifunctional power instruments, load management terminals, voltage and current loss timers, distribution automation terminals and other equipmentTesting and calibration of digital electrical measuring instruments such as energy meters, voltmeters, ammeters, phase meters, frequency meters, power meters, and power factor meters, as well as testing and calibration of electrical quantity sensors such as instrument voltage transformers, current transformers, clamp current transformers, etc, Testing and calibration of voltage transmitters, current transmitters, power transmitters, power factor transmitters, frequency transmitters, and other electrical quantity transmitters;.

IIFeatures

1The instrument is equipped withRS232Interface andRS485The interface can be operated on the whole machine through the upper computer, and the communication protocol is open.

2Equipped with an external control switch interface, it can be connected to a foot switch to control the start and stop of signals.

3The capacitive load driving capability of three-phase voltage channels.

4Adopting800×600 TFTColor LCD display screen, with all electrical parameters displayed on one screen and vector graph display function.

5When there is a voltage short circuit, current open circuit, or wiring error, the output can be automatically stopped and accompanied by an audible and visual alarm.

6Adopting power amplifier technology improves reliability and stability.

7The three-phase voltage, current, phase, power, power factor, and frequency are all high-precision and high stability standard signal outputs, with software closed-loop.

8TheYSB3060AAC/DC instrument calibratorCapable of outputting0-31Sub harmonic.

9The phases between three-phase voltages, as well as between each phase voltage and current, are all acceptable360Adjust.

10Equipped with touch screen, rotary encoder, panel buttons, and multiple operation modes.

11It has three input and output interfaces for electric energy pulses, which can simultaneously verify the errors of three single-phase or three-phase electric energy meters.

12It has the function of conducting a word test on the electric energy meter.

IIItechnical indicators

AC current output

range20AThe5AThe1AThe0.2A adjustment range: (0120)%RG Regulating fineness: 0.01%RG

Accuracy:0.1%RG

stability 0.02%/3min Output power: per phase20VA

Full load adjustment rate:0.05%RG Distortion: ≤0.2%(Non capacitive load)

2AC voltage output

range380VThe220VThe100VThe57.7V Adjustment range:(0-120)%RG Adjust fineness:0.01%RG

Accuracy: 0.1%RG

stability0.02%/3min Output power: per phase20VA

Full load adjustment rate:0.05%RG Distortion: ≤0.2%(Non capacitive load)

3active power:Accuracy:0.1%RGstability0.05%RG/3min

4 phase Position: 0°~359.99° ; Adjust fineness: 0.01°; Accuracy: 0.05°;

5frequency Rate: 40Hz70Hz Regulating fineness0.001Hz Accuracy: 0.005Hz

6Power factor: -10+1 Adjust fineness: 0.001 Accuracy: 0.005

7Harmonic output: Harmonic frequency:2-31time Harmonic content setting range:040%

Accuracy of harmonic content setting: Set value ±0.1%

8Environmental conditions: Working environment temperature: 0℃~40;relative humidity 85%

Working power supply:AC220V±15% power consumption400VA

9Specification and weight: Size:449mm×455mm×177mmWeight: 18Kg