Agilent liquid chromatography system1260 Infinity II,
characteristic
Compatible with conventional and ultra-high performance liquid chromatography: The 1260 Infinity II quaternary pump and 1260 Infinity binary pump can operate at pressures up to 600 bar, making them ideal for use with InfinityLab Poroshell 120 chromatography columns
Analytical and semi preparative purification: Wide flow rate range of 1260 Infinity II quaternary pump (up to 10 mL/min) * supports standard and semi preparative applications
Fast and Accurate Gradients: The 1260 Infinity II binary pump utilizes LC/MS and UV only systems to achieve fast and accurate gradients*
Ultra low cross contamination: The 1260 Infinity II Multisampler's multiple cleaning function can clean all relevant injection components between runs, and use the needle seat recoil program to rinse the outside of the injection needle with three solvents, reducing residue to below 10 ppm
Shorten analysis cycle: Adopting Agilent's dual needle design, samples can be run alternately through two injection channels. The analysis cycle can be shortened to a few seconds, almost eliminating traditional waiting time - whether it is large volume sampling or performing flushing steps
Efficient sample processing and workflow: The 1260 Infinity II Multisampler features shallow well plate drawers that can accommodate up to 16 microplates and 6144 samples, making it the highest capacity single system
Efficient column operation and temperature control: The 1260 Infinity II high-capacity column incubator can accommodate up to four columns and can be operated directly on each column through Quick Change to quickly change the switching valve, providing greater flexibility without disconnecting and reconnecting the columns
High quality data: The 1260 Infinity II diode array detector HS provides lower detection limits and higher data quality, giving you more confidence in the results
Efficient control, acquisition, and reporting: The Agilent Instrument Control Framework (ICF) enables smooth control of Agilent liquid chromatography instruments through third-party chromatographic data systems,
performance index
| width | |
| Intelligent System Simulation Technology | |
| Pump type | |
| flow rate range | |
| depth | |
| Maximum number of temperature zones | |
| Maximum number of solvents | |
| supply voltage | |
| System pressure operating range | |
| Column ID Reader Options | |
| Column capacity | |
| Range of injection volume |
0.1–100 μL
0.1–900 μL, Equipped with an option to expand the injection volume range
0.1–1800 μL, Equipped with multiple extraction toolkits
4
Optional
up to 600 bar
100-240 VAC
4
up to 15 with additional Solvent Selection Valve
2 with G7116A/B
1 with Vial Sampler with Integrated Column Compartment
468 mm
0.05 to 5 mL/min with G7112B
0.2 to 10 mL/min with G7110B, G7111A, G7111B
Isocratic
Binary
Quaternary
Gradient
No
435 mm