The Multiwave GO Plus microwave digestion instrument includes an exclusive directional multimode cavity (DMC), which combines the advantages and performance of single-mode and multi-mode microwaves. The microwave field automatically adjusts based on the number of installed or vacant positions and the solution volume of the reaction tube - this is a true innovation. By using turbine cooling technology, the cooling time of a fully loaded 12 position rotor can be reduced to just 8 minutes (EPA method). The intelligent pressure control technology of Multiwave GO Plus * is extremely convenient in the marketThe microwave digestion system.

The directional multi-mode cavity (DMC) of Multiwave GO Plus * can achieve efficient TURBO heating in a compact system using only one magnetron. In a single-mode system, microwaves are directed towards the sample to provide efficient heating in a small volume digestion system. In a multi-mode system, multiple different samples can be simultaneously digested.
Combined with the TURBO cooling system, Multiwave GO Plus can quickly cool from 180 ° C to 70 ° C (EPA method) in less than 8 minutes, making it the product with the shortest overall processing time on the market. This is attributed to the fit between the built-in cooling unit, exhaust system, rotor, and container (with heat sinks)Interacting and minimizing the occupied area.

The innovative intelligent pressure control technology adopts Anton Paar's pressure activation pressure control concept to ensure high-quality digestion. The container composed of three parts is resistant to hydrofluoric acid and can be closed without tools.
With the help of intelligent pressure control technology, you can:
Accurately control the pressure of each container
Safely release overpressure
Detect the increase in digestion temperature
*The weight of the sample
Safe digestion of samples with different unknown reaction types in the same batch

A wide variety of samples can be obtained with excellence in Multiwave GO PlusThe dissolution. This includes environmental samples, food and feed analysis, material testing, as well as petrochemical, plastic, polymer, cosmetic, metal, alloy, and geological samples.
By pre installing conventional methods such as EPA 3015A, EPA 3051A, or EPA 3052, a large number of samples can be easily digested, further simplifying your workflow.
Thanks to the complete microwave system in the compact design, you can perform routine digestion and extraction on high sample volumes, low sample volumes, inorganic or organic matrices.
Compliant with standards | |
ASTM |
D4309 |
EN |
13346 |
13656 | |
13657 | |
13804 | |
13805 | |
13806 | |
14083 | |
14084 | |
14332 | |
14385 | |
15297 | |
15411 | |
15763 | |
15764 | |
15765 | |
EN ISO |
15587-2 |
EPA |
3015 |
3051 | |
3052 | |
GA |
T1662 |
GB |
5009 |
T24533 | |
T26125 | |
T 36592 | |
T 36593 | |
T 38287 | |
HJ |
491 |
678 | |
680 | |
702 | |
766 | |
781 | |
803 | |
832 | |
ICH |
Q3D Guideline |
U.S. Pharmacopoeia (USP) |
232 -Elemental impurities-Limit values adopted |
233 -Elemental impurities-step | |
Chinese pharmacopoeiaChP |
2321 |
European Pharmacopoeia |
5.2 |