Overview
Ankerui Household Light Storage Anti Reverse Current Meter ADL400W is an intelligent instrument designed mainly for new energy generation systems such as photovoltaic grid connected systems, micro reverse systems, energy storage systems, and AC coupling systems. The product has the advantages of high accuracy, small size, fast response speed, and easy installation.
Product Details

Ankerui household light storage anti backflow electric meter ADL400WThe series external transformer dual circuit wireless energy meter is an intelligent instrument designed mainly for new energy generation systems such as photovoltaic grid connected systems, micro inverter systems, energy storage systems, and AC coupling systems. The product has the advantages of high accuracy, small size, fast response speed, and easy installationPoint.

Ankerui household light storage anti backflow electric meter ADL400WIt can monitor and measure real-time power parameters, support Modbus TCP, HTTP and other protocols, and communicate with inverters or energy management systems (EMS) through Wi Fi and Lora communication methods to achieve functions such as anti backflow, regulating power generation, battery charging and discharging. Bidirectional metering enables distributed photovoltaic energy management for household use.

安科瑞户用光储防逆流电表ADL400W

安科瑞户用光储防逆流电表ADL400W

安科瑞户用光储防逆流电表ADL400W

Voltage and current wiring diagram

安科瑞户用光储防逆流电表ADL400W

A single-phase electricity meter only needs to be connected to phase A; Only connect Phase A to the single-phase electric meter; ADL  - CT/ -1-  only requires CT1 connection; Only need connect CT1 to ADL-CT/-1-; For safety reasons, a fuse with a rated current of 5A needs to be connected to the voltage input terminal; For safty reasons,a fuse with a rated current of 5A needs to be connected to the voltage input terminal; Before wiring, ensure that the equipment is in a power-off state; Verify that power is OFF before making connections; Each CT group of ADL200W-CT/ has only one phase transformer, while each CT group of ADL400W-CT/ has three phase transformers. 7 Each group of CT in ADL200W-CT/-- has only one phase of transformer, while each group of CT in ADL400W-CT/-- has three phases of transformer.

安科瑞户用光储防逆流电表ADL400W