The MYPTJ-8.7/10KV high-voltage rubber sheathed cable for coal mines is one of the series of mining rubber sheathed flexible cables, suitable for use as a power connection line for ground mobile mining machinery equipment at rated voltage levels
Coal mine cable MYPTJ-8.7/10KV high-voltage rubber sheathed cable
Application of high-voltage coal mine cables:
The 6kv MYPTJ cable product is a series of mining rubber sheathed flexible cables, suitable for power connection of coal mining machines and similar equipment with rated voltage Uo/U 3.6/6KV and below.
Conditions for the use of coal mine cables
The long-term allowable working temperature of the wire core is 85 ℃, and the minimum bending radius of the wire is 6 times the diameter of the cable.
|
| 3.6/6KV shielded rubber sheathed flexible cable (GB12972.7-1991) |
| Purpose: This product is one of the series of mining rubber sheathed flexible cables, suitable for use as a power connection line for ground mobile mining machinery equipment at rated voltage levels |
| Usage conditions: The long-term allowable working temperature of the cable conductor is 90 ℃ |
|
|
|
|
| Cable specifications and names |
|
model |
name |
main purpose |
(MYP)UYP-3.6/6 |
Mining mobile shielded flexible cable |
The connection between a mobile ground mine with a rated voltage of 3.6/6KV and a mechanical power supply has a lower ambient temperature limit of -20 ℃ |
(MYPT)UYPT-3.6/6 |
Mining mobile metal shielded rubber sheathed flexible cable |
MYPTJ-3.6/6 |
Mining mobile shielding monitoring flexible cable |
Rated voltage 3.6/6KV coal mining machine cable power cable, used for power connection |
MYPTJ-6/10 |
Mining mobile metal shielded flexible cable |
|
|
|
|
|
|
|
|
| Cable specifications and dimensions |
|
|
|
|
|
|
Number of cores x nominal cross-sectional area of conductor (mm2) |
|
Nominal thickness of sheath (mm) |
UYP-3.6/6 and UYPTJ-3.6/6 cable outer diameter (mm) |
Power line core insulation |
Power cord core |
Ground wire core |
Nominal thickness (mm) |
minimum |
maximum |
3×16 |
1×16 |
4 |
5.5 |
51.3 |
57.3 |
3×25 |
1×16 |
4 |
5.5 |
53.9 |
59.9 |
3×35 |
1×16 |
4 |
5.5 |
57 |
63 |
3×50 |
1×25 |
4 |
5.5 |
60.8 |
66.8 |
|
|
|
|
|
|
Number of cores x nominal cross-sectional area of conductor (mm2) |
|
Nominal thickness of sheath (mm) |
UYP-3.6/6 and UYPTJ-3.6/6 cable outer diameter (mm) |
The power core is absolute |
Power cord core |
Ground wire core |
Edge nominal thickness (mm) |
minimum |
maximum |
3×16 |
1×16/3 |
4 |
5.5 |
51.8 |
57.8 |
3×25 |
1×16/3 |
4 |
5.5 |
54.8 |
60.8 |
3×35 |
1×16/3 |
4 |
5.5 |
58.3 |
64.3 |
3×50 |
1×25/3 |
4 |
5.5 |
61.4 |
67.7 |
|
|
|
|
| technical performance |
|
|
|
| 1. The insulation resistance value of the power core of the cable |
|
|
Nominal cross-section of power core (mm2) |
Minimum insulation resistance at 20 ℃ (M Ω· km) |
16 |
750 |
25 |
650 |
35 |
550 |
50 |
500 |
| 2. The insulation material adopts ethylene propylene rubber as the base material, and the tensile strength is not less than 6.5MPa. |
| 3. The other electrical properties and mechanical properties of insulation and sheath of electricity bills shall comply with the provisions of GB3048 and GB2951. |
|
Coal mine cable MYPTJ-8.7/10KV high-voltage rubber sheathed cable