Coal mine control cable MKVVRP - manufacturer's quotation

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Coal mine control cable MKVVRP - manufacturer's quotation $r $n for control circuits, protection circuits, and instrument connections in weak current control systems or strong electromagnetic interference areas in mines.
Product Details

Coal mine control cable MKVVRP - manufacturer's quotation

MKVV coal mine control cable, MKVVP coal mine plastic control cable, MKVV22 coal mine plastic insulated cable
Execution standard: Enterprise standard Q/TX001-2006 This standard is applicable to copper core PVC sheathed flame-retardant control cables used in coal mines.
Cable model, name, specification and purpose
model
name

Specifications

purpose
MKVV
Copper core polyethylene insulated polyvinyl chloride sheathed flame-retardant mining control cable
(2-14)*(4-6)

(2-61)*(0.75-2.5)

Installed indoors, inside cables, pipelines, and other fixed locations
MKVV22
Copper core, polyethylene insulation, polyvinyl chloride sheath, steel strip installation, flame-retardant control cable for coal mines
(7-61)*(0.75-1.5)

(4-14)*(4-6)

Installed indoors, inside cables, in pipelines, and directly buried in fixed environments that can withstand significant mechanical external forces

MKVV32

Copper core, polyethylene insulation, polyvinyl chloride sheath, steel wire, and flame-retardant mining control cable (2-61)*(0.75-2.5)

(4-14)*(4-6)

Installed indoors, inside cables, in pipelines, directly buried, suspended, and able to withstand high tensile forces in fixed situations

MKVVP22

Copper core, polyethylene insulation, polyvinyl chloride sheath, braided shielding steel strip, and flame-retardant control cable for coal mines

(4-14)*(4-6)

(4-61)*2.5mm2

Installed in high magnetic field indoor, cable indoor, pipeline, directly buried, hanging, and fixed occasions that can withstand large tensile forces

MKVVRP

Copper core polyethylene insulated polyvinyl chloride sheathed braided shielding flame-retardant control flexible cable for coal mines

(4-61)*(0.5-2.5)

(4-37)*(1.5-2.5)

Installed in fixed places such as large magnetic field rooms, cable rooms, pipelines, etc

MKVV cable, MKVVP cable, MKVVP2 cable, MKVV22 cable, MKVV32 cable, MKVVR cable, MKVVRP cable, MKVVP22 cable and other specifications and models of flame-retardant control cables for coal mines. The recommended number of cable cores is 2,3,4,5,7,8,10,12,16,19,24,27,27,30,37,44,48,52,61 cores

MKVV(2-14)*(4-6)mm2 ,(2-10)*10mm2 (2-61)*(0.75-2.5)mm2 MKVV22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 MKVVP(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 MKVVP22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2

1. Rated voltage 450/750v

2. The length of the cable conductor allows for a working temperature of 70 degrees Celsius

3. The laying temperature of the cable should not be lower than 0 degrees Celsius, and the recommended allowable bending radius;

4. The cable without armor layer should not be less than 6 times the outer diameter of the cable

5. Cables with armor or copper tape shielding structures should not be less than 12 times the outer diameter of the cable.

6. Flexible cables with shielding structures should not be less than 6 times the outer diameter of the cable.

MT386-1995 "Test Method and Judgment Rules for Flame retardancy of Flame retardant Cables for Coal Mines" and Q/TX 001-2006 "Plastic Insulated Control Cables for Coal Mines"