Product use: The fiberglass composite salt spray test chamber is used to assess the ability of materials and their protective layers to resist salt spray corrosion, as well as to compare the process quality of similar protective layers. It can also assess the resistance of certain products to salt spray corrosion; Composite salt spray corrosion testing for protective layers of components, electronic components, metal materials, and industrial products
| Equipment model |
Studio size (D * W * H) mm |
Dimensions (D * W * H) mm |
| LRHS-108-RFHY |
450×600×400 |
According to the three views of the contract |
| LRHS-270-RFHY |
600×900×500 |
| LRHS-412-RFHY |
750×1100×500 |
| LRHS-663-RFHY |
850×1300×600 |
| LRHS-816-RFHY |
850×1600×600 |
| LRHS-1080-RFHY |
900×2000×600 |
Technical Parameter
Sales Hotline: 021-608 99999
sexually ability finger treetop |
temperature range |
RT+5℃~80℃ |
| Humidity range |
30%~98% RH |
| Saturation bucket temperature |
RT+10℃~70℃ |
| temperature uniformity |
≤2℃ |
| temperature fluctuation |
±0.5℃ |
| Salt spray deposition amount |
1-2ml/80 cm ². h (16 hour average) |
| Compressed air pressure |
2.00±0.01(kg/cm²) |
| spray mode |
Continuous/Periodic Optional |
| Sample holder angle |
Can meet 15 ° and 30 ° tilt tests |
| test method |
NSS test AASS test CASS test |
send use material material |
Cabinet material |
Fiberglass material |
| Box cover material |
Fiberglass material |
| Air saturated bucket |
High quality and premium stainless steel SUS304 |
| Compressed air pipe material |
High quality rubber tubing |
| Other pipelines |
Thickened fluorosilicone rubber tube |
pit the heart join in marriage place |
temperature controller |
High quality "Youyi Control" brand temperature and humidity instrument |
| Dehumidification and cooling |
Single machine or double machine cascade refrigeration |
| compressor |
Taikang, France |
| temperature sensor |
PT100 platinum resistance thermometer |
| Heating pipe |
Titanium alloy heating tube |
| Circuit breaker |
Schneider miniature circuit breaker (prevents control circuit short circuit) |
| Standard configuration |
V-shaped sample holder, round rod, nozzle, funnel, measuring cylinder, mist tube |
| Safety protection |
Underphase/reverse phase of the whole machine, equipment timing, rapid fog removal indication, test completion Over temperature, low water level protection, leakage, short circuit, compressor overpressure overload |
| supply voltage |
AC380V±10% 50Hz |
| Power |
8.5kW/10.0kW/12.0kW/13.5kW/15.0kW/17.5kW |
send use ring area |
Temperature: |
5 ℃ to+35 ℃ (average temperature within 24 hours ≤ 28 ℃) |
| Relative humidity: |
≤85%RH |
Note: 1. The above data were measured under good ventilation conditions at an ambient temperature of 25 ℃ 2. We can customize non-standard laboratories according to specific user requirements 3. This technical information is subject to change without prior notice |