The KY-4S thiol sulfur analyzer applies the principle of fully automatic potentiometric titration to analyze and determine the thiol sulfur content in petroleum products under computer control. The instrument adopts imported titration units to smooth the titration curve and correct the endpoint position, ensuring the accuracy of the results. It is an essential instrument for petrochemical laboratories, analysis rooms, and scientific research departments. KY-4S thiol sulfur titrator - Jiangsu Keyuan

Product Details

KY-4SThiol sulfur analyzerUsing the principle of fully automatic potentiometric titration, the analysis and determination of thiol sulfur content in petroleum products are achieved under computer control. The instrument adopts imported titration units to smooth the titration curve and correct the endpoint position, ensuring the accuracy of the results. It is an essential instrument for petrochemical laboratories, analysis rooms, and scientific research departments. KY-4SThiol sulfur titrator--Jiangsu Science Park

KY-4SThiol sulfur titrator--Jiangsu Science ParkMain features of the instrument:

1.Adopting imported titration equipment. High degree of automation in computer operations and analysis of results.

2.The combination of automatic fluid replacement, fixed value fluid addition, and electromechanical organic methods.

3.Double high impedance input, automatic endpoint judgment, stable and reliable electrode potential.

Thiol sulfur titratorExecution standards:

GB/T 1792Method for determination of thiol sulfur in distillate fuels

Thiol sulfur titratorMain technical parameters:

1.Sample type: Liquid

2.Determination method: Potentiometric titration method

3.Measurement range: ≥3ug/g

4.Titration volume:0.01ml

5.Potential measurement range:(0~±1999.5mV

6.Accuracy of burette: ±0.1%F.S

7.Basic error of electronic units: full reading0.1%±0.5mV

8.Relative error: ≤5%

KY-4SThiol sulfur analyzerUsing the principle of fully automatic potentiometric titration, the analysis and determination of thiol sulfur content in petroleum products are achieved under computer control. The instrument adopts imported titration units to smooth the titration curve and correct the endpoint position, ensuring the accuracy of the results. It is an essential instrument for petrochemical laboratories, analysis rooms, and scientific research departments. KY-4S - Jiangsu Science Park