Welcome Customer !

Membership

Help

Beijing Hongzuo Shengwei Technology Co., Ltd
Custom manufacturer

Main Products:

smart-city-site>Products

Korean Eilin Acme 6100 Gas Chromatography Instrument

NegotiableUpdate on 03/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Acme 6100 GC instrument is based on 25 years of supply and production of HPLC, The exclusive technology and rich experience of GC and other analytical chromatographs have developed the highest performance gas chromatograph in Korea. From the initial development of 680AGC in 1991 to the exclusive design and development of 600DGC by South Korea in 1995, which focused on GC core technology, and in 2001 with electronic flow
Product Details
main features
1.APCFlow control function,Programmable pressure control/Flow, reduce analysis time, and improve productivity
2.
Six channel temperature control function
3.
Automatic ignition function
4.
Large screen vacuum fluorescent display
5.
Wide temperature control range:-80℃(Liquid Nitrogen)~450℃
6.
Flexible and versatile injector and detector configuration functions
7.
Automatic diagnosis of abnormal functions in the sampler and detector
8.15
Step program heating, maximum heating rate100℃/minThe function
9.
Set the diversion of the injection port/Non diversion function
10.
The various functions and settings of the injection valve
11.
Automatic repetitive analysis function
12.
Signal conversion function
13.
Capable of starting external devices
14.
preservation20An analytical method for memory function
15.
Time control function
16.
The function of installing an automatic sampler
17.
Gas control has four control modes: constant current mode, constant pressure mode, variable speed mode, and variable pressure mode
18.
The function of controlling the speed and injection depth of the automatic sampler

technical parameter
1.Column temperature box
Operating temperature:At room temperature4℃450℃
Using liquid nitrogen:- 80℃450℃
Using liquidCO2:-55℃450℃
Temperature setting resolution:1℃
Maximum temperature setting rate:100℃/min
Maximum running time: 9999min
Program heating up: fifteenrank
Temperature control accuracy: ±0.01℃
2.
Electronic flow control
At most4individualAPCThe module is used for injection ports, detectors, and auxiliary gases
Pressure increment0.1psi
Environmental pressure sensing is used to compensate for altitude and temperature variables
Both the injection port and detector can be usedAPC, used for various gas flow rates
Optional carrier gas and compensating gas:He,H2,N2andAretc.
The flow and pressure set points are displayed on the parameter screen
3.
Injection port
Maximum number of injection ports:2individual
Type of injection port:
Fill the injection port:Electronic pressure/flow,maximum450℃
Diversion/splitless:Electronic pressure/flow,maximum400℃
Pressure or flow electronic control,And the diversion ratio electronic control
Electronic control injection port:Pressure setting range: 0100psiTotal flow setting range:shunt/splitless, 0200ml/minnitrogen0100ml/miHydrogen or helium gas,Fill column injection port: 0100ml/mi,temperature stability:         ±0.01℃
4
Detector
All detectors are equipped withAPCElectronic pneumatic control
All detectors are equipped with electronic automatic gas switches
Provide detectors: FID,TCD,ECD,PDD
Temperature stability: ±0.1℃
● FID
detector
  450℃Maximum operating temperature
Automatic ignition
Fire extinguishing detection
Detection limit:10pgcarbon/second, (12Alkane meter)
Linear dynamic range: ±107
Sensitivity:19MCoulomb
● TCD
detector
  400℃Maximum operating temperature
Flow cell: Four arm rhenium-Tungsten wire
Detection limit:<10ng/ml, (12Alkane meter)
● PDD
detector
  400℃Maximum operating temperature
  PDHIDPDECDMode selection
Minimum detection quantity:
Linear:105
PDHID
Organic compounds: Less thanPPb
Permanent gas: belowPPm
PDECD
Minimum detection limit:10-15