Large sand and dust test chamber

NegotiableUpdate on 05/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product use: The large sand and dust test chamber is suitable for testing the sealing performance of product shells, mainly used for testing the IP5X and IP6X levels specified in the shell protection level standards.

Product Details

Equipment model Studio size (D * W * H) mm Dimensions (D * W * H) mm
LRHS-2000-PS 1000×2000×1000 According to the three views of the contract
LRHS-4000-PS 2000×2000×1000
LRHS-6000-PS 2000×3000×1000
LRHS-8000-PS 2000×2000×2000
Technical Parameter
Sales Hotline: 021-608 99999
sexually
ability
finger
treetop
Time setting range Adjustable from 1 to 9999H
Airflow velocity Not exceeding 2m/s
Dust blowing method ±0.5℃/±2℃
Sand and dust concentration 2~4kg/m³
Experimental dust Dry talcum powder, Portland cement, chimney ash, etc
Vacuum pump flow control 60~600L/H
Dust dehumidification Electric heating for temperature rise and dehumidification
Vibration time 1S-99H adjustable
Dust blowing time 1S-99H adjustable
Cycle period Dust blowing time, stop time, and total time can be set arbitrarily
Observation window 395 × 395mm (effective field of view)
send
use
material
material
External material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304
temperature controller Taiwan Weilun 7.0-inch color touch instrument panel
Standard configuration Sample rack, dust scraper, talcum powder
Select accessories Vacuum system: rotary vane vacuum pump (equipped with vacuum pumping pipeline components)
Safety protection Fan motor overheating, overall equipment under/reverse phase, leakage protection
Test timing, overload and short circuit protection, automatic shutdown after fault alarm
supply voltage AC380V±10% 50Hz
Power 4.5kW 4.5kW 6.0kW 6.5kW
Usage environment 5℃~+28℃ ≤85% RH
Note:
1. The test data were measured under good ventilation conditions at an ambient temperature of 25 ℃
2. The above parameters are for reference only and can be customized according to the specific testing parameters of the user
3. This technical information is subject to change without prior notice