E-mail
1400654485@qq.com
-
Phone
13621915063,13774416198
-
Address
466 Jiangyang South Road, Jing'an District, Shanghai
Shanghai Shengxu Electric Co., Ltd
1400654485@qq.com
13621915063,13774416198
466 Jiangyang South Road, Jing'an District, Shanghai
Lightning protection component testerFeatures:
The product has functions such as memory, computation, retention, self checking, and leak alarm. It has functions such as high voltage short-circuit protection, overcurrent protection, and high voltage preset. The high-pressure self release time is less than 5 seconds. The test results are displayed by two 3 1/2 LCD digital displays, one displaying voltage value and the other displaying current value, with high accuracy and good reliability. Can be used as an adjustable DC high voltage source (1kV~10kV) with an output current of ≤ 1mA.
Voltage withstand: AC 2.3kV 50Hz 1min
Working temperature and humidity: 0 ℃~+40 ℃<90% RH
Storage temperature and humidity: -10 ℃~+50 ℃<90% RH
Power supply: AC220V ± 10% 50Hz
Power consumption lt; 40W
Dimensions: 280mm (L) × 280mm (W) × 90mm (D)
Weight: ≤ 4 kg
Instrument characteristics:
(1) Suitable for testing the DC parameters of overvoltage protection components such as zinc oxide lightning arresters (varistors), metal ceramic two - and three electrode discharge tubes, vacuum lightning arresters, etc.
(2) It has functions such as high voltage short-circuit protection, overcurrent protection, high voltage preset, and range adjustment.
(3) It has a self checking and discrimination function, which can emit sound prompts for over range testing during the measurement process.
(4) It has functions of memory, computation, retention, control, and continuous testing.
(5) The test results are displayed by a 3 1/2 digit LCD digital display, which can automatically display accurate and reliable required data.
Lightning protection component testerTechnical Specifications:
(1) Varistor measurement
Technical indicators |
Measurement range |
Work error |
Test conditions |
Initial operating voltage U1mA |
0~1999V |
≤±1%±1d |
1mA±5μA |
Leakage current I0.75U1mA |
0~199.9μA |
≤±2μA±1d |
0.75U1mA≤±1%±1d |
(2) Discharge tube measurement
Technical indicators |
Measurement range |
Work error |
test conditions |
DC breakdown voltage Vsdc |
8~1999V |
≤±1%±1d |
Voltage rise rate 100V/S ± 10% |
(3) Other indicators
Insulation resistance: ≥ 10M Ω (500V)
Voltage withstand: AC 2kV 50HZ 1min
Working temperature and humidity: -5 ℃~+40 ℃ ≤ 85% RH
Storage temperature and humidity: -10 ℃~+50 ℃ ≤ 85% RH
Power supply: AC 110V/220V 50Hz/60Hz
DC 12V 0.5A
Power consumption: 10W