M-SYSTEM Love Mode Signal Isolation Converter

NegotiableUpdate on 01/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The main functions and strengths of the M-SYSTEM Love Mode Signal Isolation Converter are: converting DC signals into standard process signals, with a response time of 180 μ s, and a wide range of applicable power sources. It can be installed at high densities and has typical applications. Isolation of vibration analysis systems
Product Details


M-SYSTEM Love Mode Signal Isolation Converter

Model: M2VF ①②③④

Matters for ordering
Model code: M2VF ①②③④
① Select from the following codes.
(For example: M2VF-6A-M2/CE/Q)
Special specifications (e.g./C01/V01)

① Input signal
◆ Current input
A: 4-20mA DC (input resistance 250 Ω)
B: 2-10mA DC (input resistance 500 Ω)
C: 1-5mA DC (input resistance 1000 Ω)
D: 0-20mA DC (input resistance 50 Ω)
E: 0-16mA DC (input resistance 62.5 Ω)
F: 0-10mA DC (input resistance 100 Ω)
G: 0-1mA DC (input resistance 1000 Ω)
H: 10-50mA DC (input resistance 100 Ω)
GW: -1~+1mA DC (input resistance 1000 Ω)
FW: -10~+10mA DC (input resistance 100 Ω)
Z: Current range (refer to the "Input Specifications" section)
◆ Voltage input
3: 0-1V DC (input resistance above 1M Ω)
4: 0-10V DC (input resistance above 1M Ω)
5: 0-5V DC (input resistance above 1M Ω)
6: 1-5V DC (input resistance above 1M Ω)
4W: -10~+10V DC (input resistance above 1M Ω)
5W: -5~+5V DC (input resistance above 1M Ω)
0: Voltage Range (Refer to the "Input Specifications" section)
(Only the additional code (applicable standard) "/N" can be selected. )
01: Voltage Range (Refer to the "Input Specifications" section)
(Only additional codes (applicable standards) "/CE,/UL" can be selected. )

② Output signal
◆ Current output
A: 4-20mA DC (load resistance below 750 Ω)
B: 2-10mA DC (load resistance below 1500 Ω)
C: 1-5mA DC (load resistance below 3000 Ω)
D: 0-20mA DC (load resistance below 750 Ω)
E: 0-16mA DC (load resistance below 900 Ω)
F: 0-10mA DC (load resistance below 1500 Ω)
G: 0-1mA DC (load resistance below 15k Ω)
FW: -10~+10mA DC (load resistance below 700 Ω)
GW: -1~+1mA DC (load resistance below 7000 Ω)
Z: Current Range (Refer to the "Output Specifications" section)
◆ Voltage output
1: 0-10mV DC (load resistance above 10k Ω)
2: 0-100mV DC (load resistance above 100k Ω)
3: 0-1V DC (load resistance above 1000 Ω)
4: 0-10V DC (load resistance above 10k Ω)
5: 0-5V DC (load resistance above 5000 Ω)
6: 1-5V DC (load resistance above 5000 Ω)
4W: -10~+10V DC (load resistance above 10k Ω)
5W: -5~+5V DC (load resistance above 5000 Ω)
0: Voltage Range (Refer to the "Output Specifications" section)

③ Power supply
◆ AC power supply
M: 85-264V AC (allowable voltage range 85-264V AC, 47-66Hz)
(Only the additional code (applicable standard) "/N" can be selected. )
M2: 100-240V AC (allowable voltage range 85-264V AC, 47-66Hz)
(UL certified products are 90-264V AC)
◆ DC power supply
R: 24V DC (allowable voltage range 24V ± 10%, ripple factor below 10% p-p)
R2: 11~27V DC
(Allowable voltage range of 11-27V DC, ripple factor below 10% p-p)
(Only the additional code (applicable standard) "/N" can be selected.)
P: 110V DC
(Allowable voltage range 85-150V DC, ripple factor below 10% p-p)
(Only the additional code (applicable standard) "/N" can be selected. )

④ Additional code (can be multiple)
Applicable standards (mandatory)
/N: Not compliant with CE and UL
/CE: Compliant with CE
/UL: Compliant with UL and CE
◆ Specific specifications
(Please refer to the specific specifications for differences in specifications and combinations of codes.)
Not written: No specific specifications
/X1: Response time
(Cannot select additional code (applicable standard) "/CE,/UL". )
/X2: Input signal
(Cannot select additional code (applicable standard) "/CE,/UL". )
◆ Special specifications
Not written: No special specifications
/Q: Special specifications (please select from the special specifications separately)


M-SYSTEM Love Mode Signal Isolation Converter