E-mail
13613264222@163.com
-
Phone
13613264222
-
Address
Liuyanma Industrial Zone, Dacheng, Langfang, Hebei
Tianjin Cable Factory Rubber Cable Factory
13613264222@163.com
13613264222
Liuyanma Industrial Zone, Dacheng, Langfang, Hebei
MCP coal mining machine power cable 0.66/1.14KV
Coal mining machine cable/MCPMining cable is a power cable commonly used in mines to provide power to coal mining machines.
Mining rubber sheathed flexible cable |
||
1、 Rated voltage0.66/1.14KVSoft cables for coal mining machines and below(GB12972.2-91) |
||
This product is suitable for rated voltageUo/1.14VCopper core rubber insulated sheathed flexible cables for coal mining machines and similar equipment below |
(MC)UC-0.38/0.66 |
Rubber sheathed flexible cable for coal mining machine |
The rated voltage for coal mines is0.38/0.66KVPower connection for coal mining machines and similar equipment |
(MCP)UCP-0.38/0.66 |
Shielded rubber sheathed flexible cable for coal mining machine |
The rated voltage for coal mines is0.38/0.66KVPower connection for coal mining machines and similar equipment |
(MCP)UCP-0.66/1.14 |
Shielded rubber sheathed flexible cable for coal mining machine |
The rated voltage for coal mines is0.66/1.14KVPower connection for coal mining machines and similar equipment |
The usage characteristics of coal mining machine cables and cables |
||
1Rated voltageUo/Urespectively0.38/0.66KVand0.66/1.14KV. | ||
2The long-term allowable working temperature for cable conductors is65℃. | ||
3Cable'szuiThe small bending radius is the diameter of the wire6Twice. | ||
4The yellow sheath shall not be exposed to sunlight for a long time. | ||
×Nominal cross-section of conductor(mm2) |
outer diameter of cable |
Reference weight of cable(kg/km) |
|||||||||
Power line core insulation |
Sheath nominal |
UC-0.38/0.66 |
UCP-0.38/0.66 |
||||||||
Power cord core |
Ground wire core |
Control wire core |
Nominal thickness(mm) |
Thickness(mm) |
zuismall value |
zuiLarge value |
zuismall value |
zuiLarge value |
UC |
UCP |
|
3×16 |
1×4 |
3×2.5 |
1.6 |
4.5 |
31.4 |
35.1 |
34.7 |
38.5 |
1587 |
1897 |
|
3×25 |
1×6 |
4×2.5 |
1.8 |
5.5 |
37.8 |
42 |
41.3 |
45.5 |
2499 |
2670 |
|
3×35 |
1×6 |
4×4 |
1.8 |
5.5 |
41.8 |
45 |
45.1 |
19.5 |
3090 |
3300 |
|
3×50 |
1×10 |
7×4 |
2 |
5.5 |
46 |
50.9 |
50 |
54.3 |
3900 |
4200 |
|
XNominal cross-section of conductor(mm2) |
outer diameter of cable |
||||||
The power core is absolute |
Sheath nominal |
UC-0.38/0.66 |
Reference weight of cable |
||||
Power cord core |
Ground wire core |
Control wire core |
Nominal thickness(mm) |
Thickness(mm) |
zuismall value |
zuiLarge value |
(kg/km) |
3×35 |
1×4 |
3×6 |
2 |
6 |
47.2 |
51.4 |
3391 |
3×50 |
1×10 |
3×6 |
2.2 |
7 |
54.3 |
58.6 |
4440 |
3×70 |
1×16 |
3×6 |
2.2 |
7 |
59.6 |
64.3 |
5394 |
3×95 |
1×25 |
3×10 |
2.4 |
7 |
64.5 |
70.1 |
6775 |
MCP coal mining machine power cable 0.66/1.14KV