E-mail
2505053689@qq.com
-
Phone
13710023879
-
Address
Room 212, Huicheng Commercial Building, No. 7 Tianli Street, Dongpu Avenue, Tianhe District, Guangzhou City
Guangzhou Jichuang Electronic Equipment Co., Ltd
2505053689@qq.com
13710023879
Room 212, Huicheng Commercial Building, No. 7 Tianli Street, Dongpu Avenue, Tianhe District, Guangzhou City
PH4P-120-10-E-N/PF sensor
Yokogawa'spHThe sensor production line has been strengthened by adding polymer electrolytespHsensorPH4P/PH4PTHigh frequency resistancepHsensorPH4F/PH4FT,PH4C/PH4CTchemical processpHSensor fermentation usepHsensorPH4FEJust like the Doctor Sensor series,ORPThe sensor series is also available as a polymer electrolyteORPThe complete series of chemical processes usedOR4PTheORPSensors other than standard onesRyton pH/ORPIn addition to sensors, there are alsoOR4C.
Support pH measurement under harsh conditions, such as when the process fluid is heavily contaminated or contains sulfides.
Using polymer as the internal solution, the liquid interface is relatively large (1.0 mm~1.5 mm) and has two single pores to prevent blockage.
application
Adverse environments such as chemistry and petrochemicals
Sugar production, dyeing, industrial wastewater, papermaking
Selection Table:PH4P-120-10-E-N/PF sensor
model |
suffix |
Additional features |
remark |
PH4P |
Polymer electrolytepHsensor*1 |
||
Insert length |
-120 |
120 mm |
|
cable length |
-00 |
No Cable *3 |
|
-03 |
3m |
||
-05 |
5m |
||
-10 |
10m |
||
-15 |
15m |
||
-20 |
20m |
||
|
Terminal Type *4a |
D |
PH400GCable (fork shaped terminal) |
|
E |
forFLXA402ThePH202TheFLXA202TheFLXA21Cable (Pin Terminal) |
||
F |
FLXA202TheFLXA21Cable(M4Circular Terminal |
||
G |
forFLXA402ThePH450GThePH202/TBThe cable(M3Circular Terminal |
||
N |
wireless*3 |
||
constant term |
-N |
alwaysn |
|
|
Optional adapter*5 OCircle shaped. |
/S3 |
Stainless steel(SUS316) |
|
/PP |
polypropylene |
||
/PV |
Rigid polyvinyl chloride |
||
/PF |
Perfluoroelastomer(FFKM)*6 |
*1:PH4PandPH4FCan be connected to a temperature sensorSA405Use the adapter together.
*2:TIIS ExIntrinsic safety structure(TIIS ExCertification is only valid in Japan
*3: When using only sensors, please select the cable length-00And terminal typeN.
*4: When using a junction box, please refer to the table2.
*5: When using the holderPH8HSorPH8HFIt is necessary to do so. But when usingPH4PorPH4FtimesensorSA405No need to choose an adapter.
*6: When the sensor is used in organic solvents, highly alkaline or high-temperature alkaline solutions, choose perfluoroelastomers.