- Phone
-
Address
1606, Block A, Langqin International Building, No. 168 Guang'anmen Outer Street, Xicheng District, Beijing
Beijing Baoyun Xingye Science and Trade Co., Ltd
1606, Block A, Langqin International Building, No. 168 Guang'anmen Outer Street, Xicheng District, Beijing
Product Introduction
Spectral gamma and gamma neutron personal radiation detectors are recommended for use by security and police forces,. Their earthquake resistant surgery is specifically designed for applications in outdoor and harsh environments. PM401MB Gamma and PM1401GNB Gamma - nSpectral personal radiation detectorSPRDs are designed to detect radioactive materials and nuclear materials, while assessing their harm to the public through the identification function of radioactive isotopes.
The instrument consists of two independent parts: PM1401MB/PM1401GNB radiation detector equipped with Bluetooth mode and all identification software for data processing and radioactive isotope identification. External computing devices such as smartphones PDA、 Laptops or PCs can run PoliIdentify software. Establish communication between the Bluetooth channel radiation detector and external computing devices. This configuration provides end-users with high flexibility and convenience. For example, the radiation detector part can be used as a traditional independent personal radiation detector (PRD), which not only reduces the cost of the instrument, but also provides beginners with the ability to upgrade the instrument in the future with recognition and networking functions. In addition, Bluetooth communication allows users to perform PM1401MB/GNB operations at a safe distance from the radiation source. Preventing the operator of the instrument from receiving unnecessary radiation.
In addition to conducting network analysis on-site, the SPRD mode can also transmit data to the field for analysis and identification through the Internet.
The additional features of SPRD based on PM1401MA and PM1401GNA modes are summarized as follows:
Bluetooth communication: The instrument is equipped with Bluetooth mode communication and is used to connect with computer devices, including smartphones, in Bluetooth mode, PADS, Laptops and desktops. Bluetooth mode allows users to operate at a safe distance away from the radiation source, providing them with a high level of protection while SPRDs are in operation, preventing exposure to radiation at that distance.
Isotope identification software determines that a series of isotope identification software applications can be installed on an external computer device, such as a smartphone, PADs, Laptops and desktop computers. It provides the ability to transmit total counts and accumulate energy spectra to off-site computer devices. It is possible to identify multiple isotopes simultaneously. The identification software can be used in two operating modes: automated mode without trained users and expert mode for advanced users.
Networking software: It can use GSM communication to transmit real-time data between on-site users and remote joint command centers. Named as the Nuclear Protection Network (NPNET) ™) The networking software of the system is often used by experts in the joint command center. Through (NPNET) ™) The system allows experts to draw online information about dose rates, gamma scintillation spectra, detect and identify isotopes, locate sources with GPS, map areas, and monitor radiation levels in monitoring areas.
Application field
1. Solution
2. Security Bureau and Police
|
PM1401MB |
PM1401GNB |
|
|
detector |
||
|
γ |
CsI(Tl) |
CsI(Tl) |
|
中子 |
|
He-3 |
|
sensitivity |
||
|
relative to137Сs |
100 (s-1)/(μSv/h) |
100 (s-1)/(μSv/h) |
|
relative to241Am |
100 (s-1)/(μSv/h) |
200 (s-1)/(μSv/h) |
|
Energy Range |
||
|
γ |
0.033 – 3.0 MeV |
0.033 – 3.0 MeV |
|
中子 |
|
From thermal energy to14.0 MeV |
|
dose rate |
||
|
γ |
0.01 – 99.99 μSv/h |
0.01 – 99.99 μSv/h |
|
中子 |
|
1 - 999 s-1 |
|
dose |
|
|
|
accuracy |
±30% (in range 0.1 – 70 μSv/h |
±30% (in range 0.1 – 70 μSv/h |
|
response time |
0.25 s |
0.25 s |
|
Identification of radioactive isotopes |
||
|
Special nuclear materials(SNM) |
233U,235U,237Np, Pu |
233U,235U,237Np, Pu |
|
Medical radioactive isotopes |
18F,67Ga,51Cr,75Se,89Sr, |
18F,67Ga,51Cr,75Se,89Sr, |
|
Naturally occurring radioactive isotopes(NORM) |
40K,226Ra,232Th and daughters, |
40K,226Ra,232Th and daughters, |
|
Industrial radioactive nuclide |
57Co,60Co,133Ba,137Cs,192Ir, |
57Co,60Co,133Ba,137Cs,192Ir, |
|
Compliant and qualified |
ITRAP/IAEAdemand, |
ITRAP/IAEA rdemand, |
|
alarm method |
Vision, sound, vibration |
Vision, sound, vibration |
|
data recording |
1000 |
1000 |
|
Environmental level protection |
IP65 |
IP65 |
|
Drop floor test |
1.5 m (4.9 ft) |
1.5 m (4.9 ft) |
|
battery supply |
aAAbattery |
aAAbattery |
|
battery life |
1000 hour |
1000 hour |
|
Operating temperature |
-30°C—50°C |
-30°C—50°C |
|
size(No leather cover) |
103 x 57 x 32 mm |
194 x 57 x 32 mm |
|
weight |
||
|
(No leather cover) |
270 g ( 9.52 oz) |
430 g (15.2 oz) |
|
Low battery warning |
LCD |
LCD |
|
Overload alarm value |
||
|
γ |
OL |
OL |
|
中子 |
|
999 |
|
contact method |
Infrared data communication, Bluetooth |
Infrared data communication, Bluetooth |