Photovoltaic (PV) module UV test chamber

NegotiableUpdate on 09/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product use: The UV test chamber for photovoltaic (PV) modules mainly specifies the test for assessing the anti UV radiation ability of PV modules when exposed to UV radiation environment. This test is suitable for evaluating the anti UV radiation performance of storage polymer materials, protective layers and other materials

Product Details

Device Model Effective irradiation area (D * W) mm Dimensions (D * W * H) mm
LRHS-S-NGF 600×1270 750×1880×800
LRHS-H-NGF 1820×1000 1400×2500×1500
Technical Specifications
Sales Hotline: 021-608 99999
sex
can
point
mark
Component surface temperature 60℃
temperature fluctuation ± 0.5 ℃ (when unloaded)
Center distance of the lamp 70mm
Illuminance The uniformity of the component testing surface is ± 15%
Wind speed 0.5~1.0m/s
Light source 6 units (Q-Lab, a well-known American brand)
Wavelength 280~320nm(UVA-340) 和313~340 nm(UVB-313)
Distance between the sample and the parallel plane of the lamp Finally meet the wavelength requirements for sample testing (the height of the specimen table can be adjusted)
make
use
material
material
outer box material High quality A3 steel plate electrostatic spraying
Inner box material SUS304B brushed plate that is acid resistant, corrosion-resistant, and easy to clean
temperature sensor STT-R Platinum Resistors
circulatory system Imported snail style fan
Handheld radiometer Beijing Normal University
Standard Configuration 1 sample shelf, 8 imported light tubes, and 1 handheld radiometer
safety protection Fan overheating, overall equipment under/reverse phase, over temperature protection, test timing, leakage protection
The power distribution control cabinet is equipped with power-off protection, operation indication, automatic shutdown after fault alarm, and other protections
power supply voltage AC380V±10% 50Hz
Power 3.0kW
Usage environment 5℃~+28℃ ≤85% RH
Note:
1. Non standard customization of photovoltaic (PV) module UV test chambers can be carried out according to specific testing requirements of users