Rubber cable YCW3 * 25+1 * 10 Flexible cable YCW4 * 25+1 * 10 Price
Main performance:The rated voltage U0/U is 300/500 (YZ type) and 450/750 (YC type); The long-term working temperature of the wire core should not exceed 65 ℃; The "W" type cable has weather resistance and certain oil resistance, making it suitable for use outdoors or in contact with oil stains; The secondary ground voltage of the welding machine cable shall not exceed 200V AC and 400V DC peak.
General rubber sheathed cables are generally classified into "light, medium, and heavy" structures.YQ-0.3/0.5, YQW-0.3/0.5 lightweight rubber sheathed flexible cable, used for lightweight mobile electrical equipment and tools
YZ-0.3/0.5 ordinary medium-sized rubber sheathed flexible cable YZW-0.3/0.5 ordinary chloroprene rubber and other equivalent synthetic elastomer rubber flexible cables, used for various mobile electrical equipment and tools
YC-450/750, YCW-450/750 heavy-duty rubber sheathed flexible cable, YH high-strength welding machine rubber sheathed flexible cable, used for various mobile electrical equipment, can withstand large mechanical external forces.
Rubber cable YCW3 * 25+1 * 10 Flexible cable YCW4 * 25+1 * 10 Price
model |
name |
Scope of application |
YQ-0.3/0.5 |
Light rubber sheathed cable |
Used for lightweight mobile electrical equipment and tools |
YZ-0.3/0.5 |
Medium sized ordinary strength rubber sheathed flexible cable |
|
YZW-0.3/0.5 |
Ordinary chloroprene or other equivalent synthetic elastomer rubber sheathed flexible cable |
Used for various mobile electrical devices and tools |
YC-450/750 |
Heavy duty rubber sheathed flexible cable |
Used for various mobile electrical devices, capable of withstanding large mechanical external forces |
model |
Product Name |
Voltage KV |
Number of cores No.of |
Cross section mm2 |
Main application scope |
YZW |
Medium sized rubber sheathed flexible cable for outdoor use |
300-500 |
2 |
0.75-6 |
Used for various mobile electrical equipment with AC voltage of 450/750V and below, capable of withstanding large mechanical external forces, long-term working temperature should not exceed 65 ℃, suitable for outdoor or oil contaminated environments. |
YCW |
Heavy duty rubber sheathed flexible cable for outdoor use |
450-750 |
1 |
1.5-400 |
Used for various mobile electrical equipment with AC voltage of 450/750V and below, capable of withstanding significant mechanical external forces, suitable for outdoor or oil contaminated environments, and should not exceed 60 ℃ for long-term operation |
Basic process flow of cable manufacturing
1. Copper and aluminum monofilament drawing
Copper and aluminum rods commonly used in wires and cables are drawn through one or several stretching molds using a drawing machine at room temperature to reduce their cross-section, increase their length, and improve their strength. Drawing is the first process of various wire and cable companies, and the main process parameter of drawing is mold matching technology.
2. Single wire annealing
Copper and aluminum monofilaments are heated to a certain temperature to improve their toughness and reduce their strength through recrystallization, in order to meet the requirements of wire and cable for conductive cores. The key to annealing process is to prevent oxidation of copper wire
3. Twisting of conductors
In order to improve the flexibility of wires and cables for easy installation, the conductive core is made up of multiple single wires twisted together. From the twisting form of the conductive wire core, it can be divided into regular twisting and irregular twisting. Irregular twisting can be divided into bundle twisting, concentric compound twisting, special twisting, etc.
In order to reduce the occupied area of wires and shrink the geometric dimensions of cables, a compression form is adopted while twisting conductors, transforming ordinary circles into semicircles, sectors, tile shapes, and compressed circles. This type of conductor is mainly used in power cables.
4. Insulation extrusion
Plastic wires and cables mainly use extruded solid insulation layer. The main technical requirements for plastic insulation extrusion are:
4.1. Eccentricity: The deviation value of the extruded insulation thickness is an important indicator of the extrusion process level, and most product structural dimensions and their deviation values are clearly specified in the standard.