gasket
  • Improper use or use of old gaskets to connect chromatography columns can result in inconsistent chromatographic peaks and unreliable results. Using inappropriate sealing gaskets can allow air and other pollutants to seep into the chromatographic system through the column seal, seriously affecting column efficiency and detection performance. To maintain optimal performance of the instrument, the sealing gasket should be replaced every time the chromatographic column is replaced or maintained.
  • There are three main types of gaskets used for GC capillary columns, namely graphite gaskets, Vespel gaskets, and Vespel graphite gaskets. The graphite pad can withstand high temperatures up to 450 ℃, while Vespel and Vespel graphite pads can withstand temperatures of 280 ℃ and 350 ℃, respectively.
  • Agilent provides users with a variety of sealing gaskets in different types, materials, and shapes to ensure proper matching with the instrument and leak free connection between the chromatography column and the injection port.
Item Number
Product Name
Specifications
packaging
5080-8853()
Universal graphite pad (short pad)
Inner diameter of gasket: 0.5mm; inner diameter of column: 0.1mm, 0.2mm, 0.25mm, 0.32mm;
10/pack
5080-8773()
Universal graphite pad (short pad)
Inner diameter of gasket: 1.0mm; inner diameter of column: 0.53mm
10/pack
500-2114(5002114)
Universal graphite pad (short pad)
Inner diameter of gasket: 0.4mm; inner diameter of column: 0.05mm-0.25mm
10/pack
500-2118(5002118)
Universal graphite pad (short pad)
Inner diameter of gasket: 0.8mm; inner diameter of column: 0.45mm, 0.53mm
10/pack
5062-3516()
85%Vespel, 15% graphite pad (short pad)
Inner diameter of gasket: 0.3mm; inner diameter of column: 0.1mm, 0.2mm
10/pack
5181-3323()
85%Vespel, 15% graphite pad (short pad)
Inner diameter of gasket: 0.4mm; inner diameter of column: 0.1mm, 0.2mm, 0.25mm
10/pack
5062-3514()
85%Vespel, 15% graphite pad (short pad)
Inner diameter of gasket: 0.5mm; inner diameter of column: 0.32mm
10/pack
5062-3512()
85%Vespel, 15% graphite pad (short pad)
Inner diameter of gasket: 0.8mm; inner diameter of column: 0.45mm, 0.53mm
10/pack
5062-3507()
Pre aged 85% Vespel, 15% graphite pad (long pad) *
Inner diameter of gasket: 0.3mm; inner diameter of column: 0.1mm
10/pack
These gaskets are recommended for use in Agilent GC/MS transmission lines with 05988-20066MS interface chromatography column nuts
5062-3508()
Pre aged 85% Vespel, 15% graphite pad (long pad) *
Inner diameter of gasket: 0.4mm; inner diameter of column: 0.1mm, 0.2mm, 0.25mm
10/pack
These gaskets are recommended for use in Agilent GC/MS transmission lines with 05988-20066MS interface chromatography column nuts
5062-3506()
Pre aged 85% Vespel, 15% graphite pad (long pad) *
Inner diameter of gasket: 0.5mm; inner diameter of column: 0.32mm
10/pack
These gaskets are recommended for use in Agilent GC/MS transmission lines with 05988-20066MS interface chromatography column nuts
5062-3538()
Pre aged 85% Vespel, 15% graphite pad (long pad) *
Inner diameter of gasket: 0.8mm; inner diameter of column: 0.53mm
10/pack
These gaskets are recommended for use in Agilent GC/MS transmission lines with 05988-20066MS interface chromatography column nuts
5181-3322()
100% Vespel efficient sealing gasket (short gasket) * *
Inner diameter of gasket: 0.4mm; inner diameter of column: 0.1mm, 0.2mm, 0.25mm
10/pack
These gaskets are only recommended for use in constant temperature analysis
5062-3515()
100% Vespel efficient sealing gasket (short gasket) * *
Inner diameter of gasket: 0.5mm; inner diameter of column: 0.32mm
10/pack
These gaskets are only recommended for use in constant temperature analysis
5062-3511()
100% Vespel efficient sealing gasket (short gasket) * *
Inner diameter of gasket: 0.8mm; inner diameter of column: 0.45mm, 0.53mm
10/pack
These gaskets are only recommended for use in constant temperature analysis
5062-3580()
Special sealing gasket, 85% Vespel, 15% graphite
Double hole; 0.4 inner diameter hole; Column inner diameter: 0.1mm, 0.2mm, 0.25mm
10/pack
5062-3581()
Special sealing gasket, 85% Vespel, 15% graphite
Double hole; 0.5 inner diameter hole; Column inner diameter: 0.32mm
10/pack
5181-3308()
Special sealing gasket, 85% Vespel, 15% graphite
non-porous
10/pack